Refresh previous_cmd_ms during run_z_probe() to prevent:
stepper shutdown for expired DEFAULT_STEPPER_DEACTIVE_TIME
and extrudes for expired EXTRUDER_RUNOUT_SECONDS
(https://github.com/MarlinFirmware/MarlinDev/issues/238)
In the wait loops of M109 M190 idle() is called, what checks
stepper_inactive_time against previous_cmd_ms.
Because we can be several minutes inside the loop, resetting
previous_cmd_ms only outside the loop caused stepper shutdowns.
The name of previous_cmd_ms does not really reflect its use. It's set
not only when a new command was received or executed but also in many of
the movement routines. For that the little extension of using it during
the wait will (hopefully) not hurt.
# Conflicts:
# Marlin/Configuration_adv.h
Make stepper shutdown after inactivity dependent on a new set of
#defines.
DISABLE_INACTIV_X
DISABLE_INACTIV_Y
DISABLE_INACTIV_Z
DISABLE_INACTIV_E
And make exemplaric Configuration.
Names can be discussed.
This makes the disabling of the steppers independent from the DISABLE_?
settings witch shut down the steppers immediately.
Introduce additional variable axis_homed to replace axix_known_position
when the coordinate display should indicate the axis is not homed.
This is to distinguish between "not homed" and "inexact position possible
because stepper was disabled".
# Conflicts:
# Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
@thinkyhead
Hi Scott,
your code from a0f362c@thinkyhead is great, but you forgot to skip the
command.
Symptom `M117 Test`shows `M117 Test` on LCD instead of `Test`.
see also
https://github.com/MarlinFirmware/Marlin/commit/a0f362c735401ebbcd95de3f
6f8e3c2f17ecc770 lines 941, 2851 and so on
Greetings and welcome back
Jochen
Replace the "ok" in M280, M301, M304, M851 with output not including an "ok"
to avoid senting two "ok"s for a single g-code.
Doing the same for M105 would break the input filters of the hosts.
For M105 the other "ok" is omitted.
Make the output of M105 more similar to Repetier.
Make the text-print pert of M105 an extra function to make it reusable. `print_heaterstates()`
Use `print_heaterstates()` in M019, M190 and M303
Currently we use the probe exclusively as a device to find the build platform(bed).
For the currently supported setups this means, we use it as a additional min-endstop.
A triggered when not deployed probe disturbs the homing process for max-endstops.
Rename ENDSTOPPULLUP_ZPROBE to ENDSTOPPULLUP_ZMIN_PROBE
Rename Z_PROBE_ENDSTOP_INVERTING to Z_MIN_PROBE_ENDSTOP_INVERTING
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Rename DISABLE_Z_PROBE_ENDSTOP to DISABLE_Z_MIN_PROBE_ENDSTOP
Rename Z_PROBE_REPEATABILITY_TEST to Z_MIN_PROBE_REPEATABILITY_TEST
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Adjust comments accordingly
Remove Z_MAX check for the probe in update_endstops().
Using an delta related idea of @clefranc from #61,
extended to the general change for all setups.
Tested with Prusa i3, max-z-endstop and permanently triggered z-probe.
Worked for @clefranc's delta.
Just the minimal changes to qr_solve.cpp and .h to get rid of malloc() and free().
Saves about 656 bytes of progmem (library-code)
and 22 bytes for static variables.
Should use exactly the same amount of stack as it did before on the heap.
Updates to `set_homing_bump_feedrate`:
- Move the string into Program Memory, reduce length by 31 bytes
- Use an auto to get the divisor, adjust it on error
- Set feedrate once, at the end
- Have `Servo::attach` explicitly return -1 if it fails
- Check for -1 in `Servo::move` because `servoIndex` might be 0
- Make `attach` / `detach` calls conditional on `SERVO_LEVELING`
- Move `SERVO_LEVELING` define to `Conditionals.h`
by replacing the sequences (attach, write, delay, detach), and their conditions with the new function in Marlin.main.cpp
and removing the old configuration in the ABL part of Configuration.h
verified via 1.0.2 tag that compiles by multiple people,
credit for the fix goes to paulusjacobus for the initial find and
sniffle for the correction so M851 works.
by:
Moving HAS_LCD_BUZZ macro to Coditionals.h
Renaming HAS_LCD_BUZZ to HAS_BUZZER to make clear is has nothing to do with the lcd.
Removing the ULTRALCD condition.
Moving declaration of lcd_buzz() out of the ULTRA_LCD block in ultralcd.h
Moving definition of lcd_buzz() out of the ULTIPANEL block in ultralcd.cpp
Renaming lcd_buzz() to buzz() to make clear is has nothing to do with the lcd.
All buzzing code is now only dependent on the existence of a BEEPER-pin or the definition of a LCD_USE_I2C_BUZZER.
To do: Check the conditions for the BEEPER-pin in all pin-files.
Now send only temperature for T or B, but not send OK.
Host interprets the line to show the right temperature, but not in
response to M105 then stop and send commands until it ends the autotune.
- Use `setTargetedHotend` in `M200`, as with other commands that use
`T` for the extruder
- Synthesize the "invalid extruder" message, obviating several long
strings
- The command parser now displays “unknown command” in more cases.
Known commands must be added to the `switch` inside `process_commands`
to suppress the error.
- Use a global pointer for the current sanitized command
- Pre-sanitize the current command to bypass `N` and nullify `*`,
removing the need for handlers to bypass, ignore, or nullify these
parts, and reducing overhead for `code_seen`, etc.
- Pre-skip leading whitespace.
- Only look for G, M, T codes at the start of the command.
- Verify that G, M, T codes are followed by command codes.
- For better encapsulation add inlines for each prepare_move type
- Move controllerFan vars inside the function as statics
- Some formatting cleanup
- Rename `ClearToSend` as `ok_to_send`
- Make thermal protection for all hotends and/or bed into simple
switches
- Now enable `WATCH_TEMP_PERIOD` when `THERMAL_PROTECTION_HOTENDS` is
enabled
- Move detailed thermal parameters to `Configuration_adv.h`
- Add sanity checks to warn about old configurations
- Change `WATCH_TEMP_PERIOD` to seconds instead of milliseconds
ok N(linenumber) P(bufferremaining)
the host can use this to send the data much faster.
Some pseudo code:
If (bufferremaining > 0) send command
## as long there is free buffer send command
Also
if (linenumber > lastsend - bufferremaining) send command
## as long last linenumber received is bigger than lastsend (host) - last bufferremaining received
This addresses comments in #1956 and #1079. In particular, this is useful
when both endstops are stationary on a CoreXY system, and the Y axis needs
to be homed before the X so the flags are aligned.
With these changes the output of `M503 S0` is all you need to restore
the EEPROM. Building on this it is straightforward to save and restore
the EEPROM state using the SD card or external GCode file.
- Added `M145` to set “heatup states” for the LCD menu
- Added `M420` to toggle Mesh Bed Leveling
- Added `M421` to set a single Mesh coordinate
- Extended `Config_PrintSettings` with added M codes
- Cleaned up some comments here and there
- Add `M111` as a standard option to set the debug level
- Implement `DEBUG_ECHO` in `process_commands`
- Other debug levels (e.g., `DEBUG_DRYRUN`) need more work
Centralised beep code to lcd_buzz().
From gcode_M300() and lcd_quick_feedback().
Enforced max. duration for M300 to 5 seconds.
Corrected description in 'Configuration.h'
LCD_FEEDBACK_FREQUENCY_HZ 0 gives now a silent delay of
LCD_FEEDBACK_FREQUENCY_DURATION_MS.
- Prevent `Z_SAFE_HOMING` from homing Z twice in some cases
- Allow `G28` with XYZ values of 0 to explicitly set the position
- Don’t add `home_offset` when setting XYZ explicitly in `G28`
- Add `code_has_value` function to check for the presence of a numeric
value (could just test for space or nul to allow other types of values)
- Add comments documenting `thermal_runaway_protection`
- Add an enum for the thermal runaway states
- Add macros for temperature helper functions
- Fix a glitch with the z probe sled in homeaxis
Updated documentation in Configuration.h.
Cleaned up and commented some code relating to Z_PROBE_ENDSTOP.
Separated Z_MIN_ENDSTOP and Z_PROBE_ENDSTOP completely.
- Include the current Z when raising the axis after and between probing
- Add `sync_plan_position_delta` for parity with `sync_plan_position`
- Clean up and clarify `M48`, `dock_sled`, and others
The current position needs to be updated by using the inverse
`plan_bed_level_matrix` on X, Y, and Z. All moves in the planner are
transformed by the `plan_bed_level_matrix` from this point forward.
Documented some additional areas that should be addressed if Z_PROBE is
fully separated from Z_MIN or Z_MAX.
Fixed a documentation error in sanity checks. Servos start at 0 not 1.
- Some messages should not expire with `PROGRESS_MSG_EXPIRE`.
- Simplify conditional for progress bar with sanity checks.
- Rename `messageTick` to `expireStatusMillis` and make it the expire
time.
A `z_before` value is passed to probe_pt, but the `retract_z_probe`
function assumes that Z is 0, doesn’t add `current_position[Z_AXIS]` as
other cases do. This may be superfluous, so this is a test, and will be
reverted if it has no effect.
- Fix `prepare_move` function not calling `adjust_delta`
- Add more shorthand for plan_buffer_line.
- Fix wrong `federate` usage, assuming they are all mm/m
- Minor `stepper.cpp` cleanup
- Users prefer `G29 E` to work like `M48 E` so fixed that
- `M48 n` replaced with `M48 P` (or `p`). `n` legacy support
- Shorten some strings to save precious bytes
- Smaller code for 3-point probing
- Fixed a typo causing G28 to home incorrectly
- Added documentation to G28
- Added homeXYZ bools to neaten the code
- Added a note about home_offsets being questionable
- Add some documentation to planner and stepper headers
- Patch up RAMBO pins with undefs
- Add `sync_plan_position` inline to set current XYZE
- Swap indices in `extruder_offset` to fix initialization values
Z_DUAL_ENDSTOPS is a feature to enable the use of 2 endstops for both Z
steppers - Let's call them Z stepper and Z2 stepper.
That way the machine is capable to align the bed during home, since both
Z steppers are homed.
There is also an implementation of M666 (software endstops adjustment)
to this feature.
After Z homing, this adjustment is applied to just one of the steppers
in order to align the bed.
One just need to home the Z axis and measure the distance difference
between both Z axis and apply the math: Z adjust = Z - Z2.
If the Z stepper axis is closer to the bed, the measure Z > Z2 (yes, it
is.. think about it) and the Z adjust would be positive.
Play a little bit with small adjustments (0.5mm) and check the
behaviour.
The M119 (endstops report) will start reporting the Z2 Endstop as well.
- Add `Conditionals.h` with calculated configuration values
- Add `SanityCheck.h` with checks for configuration errors
- Remove equivalent code from all configurations
- Move error checks from some sources to `SanityCheck.h` also
- Fix initialization of count_direction in stepper.cpp
- Add BIT and TEST macros
- Add _APPLY_ macros to stepper.cpp to help with consolidation
- Consolidate code in stepper.cpp using macros
- Apply standards in stepper.cpp
- Use >= 0 instead of > -1 as a better semantic
- Replace DUAL_Y_CARRIAGE with Y_DUAL_STEPPER_DRIVERS
Added option to set Travel Acceleration (non printing moves).
The M204 options was a non sense (S for printing moves and T for retract
moves).
It has been changed to:
P = Printing moves
R = Retract only (no X, Y, Z) moves
T = Travel (non
printing) moves
I will add this info o G-Code wiki in reprap.org. I also advise to put
this info in Marlin next version changelog.
With this change a mechanical or optical switch may be used to check the
availability of the filament and when the filament runs out an M600
(filament change) command is issued. This is only done while printing
with an SD card.
This feature was requested several times (issue #679), but the requests
were not accepted since it was believed that this situation should be
handled at host side. However during an SD print the control is totally
on firmware and I think that during an SD print it should be handled by
the firmware.
The original code was posted at reprap forum
(http://forums.reprap.org/read.php?1,297350) by Lazymonk. I have only
corrected some bugs of the code and improved it by adding definitions to
the configuration.h in order to make it more standardized.
- Nonlinear auto bed leveling code (includes G29, G30, Z_RAISE_AFTER_PROBING). Cleaned it up to be a delta-specific AUTO_BED_LEVELING_GRID code path.
- Allen key z-probe deployment and retraction code. Cleaned it up and added safety checks.
- Moved sanity-checks to Marlin_main.cpp
- Applied to other configuration files
- Fixed formatting of ABL output
- Passing verbose level to probe_pt
- Miscellaneous cleanup
- Put CONFIG_STEPPERS_TOSHIBA into Configuration.h
* "G1 X1 ; test" was not executing "G1 X1" due to never leaving comment mode.
* "M117 Hello \;)" printed "Hello \" to the display due to not replacing serial_char properly.
Tested with the following commands:
* M117 Hello ; test => displays "Hello" on display, ignores "test"
* G1 X1 ; foo => moves 1mm in X, ignores "foo"
* ; test => completely ignored, not even acknowledged
* M117 Hello \;) => displays "Hello ;)" on display
* M117 Hello \\;) => displays "Hello \" on display, ignores ")"
- Adapted “Enhanced G29” code referred to in #1499 and posted at
[3dprintboard.com](http://3dprintboard.com/showthread.php?3105-Auto_Bed_
Leveling-Enhanced-G29-command)
- Compatible with current G29 while adding some new arguments
- `V` sets the verbose level for serial out
- `T` (or `V` > 2) send a Topology report to serial out
- `E` works the same way as before
- `P` works as before (source used `n` or `U`/`u`)
- `L`, `R`, `B`, `F` work as before
- Still needs sanity checking for `LRBF`
The `float` keyword should not be on these vars because they conceal
the outer vars, preventing them from obtaining known values before
being passed in `set_bed_level_equation_3pts`. Possibly related to
`Z_RAISE_BETWEEN_PROBING` not functioning.
When probing PCB´s I had the problem that i needed auto-leveling for specific areas (it´s never the same size).
Not much code, but very useful.
Now I use simply G29 L5 R55 F5 B35 P3 to probe a 4x6cm PCB before milling.
I used int for values... might be wrong...
I hope this time I got the right development tree. (tried first with https://github.com/MarlinFirmware/Marlin/pull/1130/commits)
I've insert the define and pointer entries for the Viki 2 and miniViki
from Panucatt in all of the example configs and main config. With these
additions and with pins done in the old single pin.h style...I was able
to get the display working fine save for needing to turn Delta Segments
per Second down. But that's a common graphics lcd issue being looked
into right now.
I need assistance in understanding how the new divided pins files fit
together because my previous attempts at trying to get it to work
appropriately didn't seem successful. This originally came from trying
to find out how to swap the XYZ Min and Max Endstop pins in the Azteeg
X3 Pro. It only comes with one set of connectors and they're Min
Endstops. My previous experience didn't turn out well trying to tell the
firmware to home to the Min Endstops so the best solution I found was to
swap the pins in the firmware. If I'm missing a conflict with a setup
other than delta please let me know, but it makes sense in my setup.
Update ConfigurationStore to always write dummy values for disabled
options, including FWRETRACT, DELTA, and SCARA. Update the EEPROM
version to “V15.” Also fixes a buffer overrun with axis_scaling in
Config_ResetDefault.
* Adds config parameter `PID_PARAMS_PER_EXTRUDER` - allows single PID
parameters to be used where this would be preferable (e.g. dual
identical extruders)
* When disabled, will use `float Kp, Ki, Kd, Kc;` as before.
Preprocessor macros used to switch between.
* ultralcd.cpp defines extra menus for extra parameters only where
required
* M301 reports `e:xx` only if independent pid parameters enabled
* EEPROM structure still leaves space for 3 extruders worth, when undef
will save single parameter to all extruder positions, but only read the
first
* Switching off saves approx 330 B with no LCD enabled, 2634B with LCD
(RRD) enabled: this is significant.
* LCD modifications should be tested.
This change introduces an improvement to G29 command on Marlin.
Auto bed leveling operation's reliability is based on the repeatability of the Z-probe switch and the servo. This change introduces an option to G29 command. When the G29 command is sent with an "e" option, during auto bed levelling the servo is not retracted between probes which decreases the bias on auto bed levelling resulting from servo.
G29 command does the auto bed probing as it is.
G29 E command engages the servo on first probing point, probes all points and retracts the servo after probing the last point.
Please comment your opinions, test on your printer and check the code on a programmer's perspective. (I am not a good programmer.)
* Variables Kp, Ki, Kd, Kc now arrays of size EXTRUDERS
* M301 gains (optional, default=0) E parameter to define which
extruder's settings to modify. Tested, works with Repetier Host's EEPROM
config window, albeit only reads/updates settings for E0.
* All Kp, Ki, Kd, Kc parameters saved in EEPROM (version now v14), up to
3 extruders supported (same as Marlin in general)
try, try again.
If 'OK' is garbled on sending PC won't receive it. Both machines will
wait on each other forever. This resends OK if nothing is heard from PC
for a while to avoid this bad case.
void manage_inactivity(bool ignore_stepper_queue=false)
standard is false so it is not necessary to change additional code. this
change should be better, hopefully nophead like this :)
- Fixed issue when BAL area probing is shorter than it should be for
grid probing
- Warning when BAL activated with Delta Kinematics
- Fix XY_TRAVEL_SPEED when homing Z axis
in
G0 to G3 were previously acknowledged in the get_command method, causing
them to be possibly acknowledged before commands coming after them that
were acknowledged in process_commands.
This patch fixes this, moving the acknowledgement of G0 to G3 to the
process_commands method as well. These commands are therefore no
longer acknowledged when the enter the cmd_buffer but instead only
acknowledged when the enter the plan_buffer.
Guaranteeing that commands are acknowledged in the same order in which
they were received by the firmware allows host software to be able to
track the life cycle of commands and such a better management of the
firmware's serial buffers as well as better internal command processing
and response parsing without having to depend on throwing an epic
amount of regular expressions against each line received back from the
firmware.
FixesErikZalm/Marlin#1147
Improvement to avoid reinitializing delay buffer with every print. Fixed
issues in buffer indexing and memory out of bounds due to floating point
imprecision. Simplified the code by avoiding conversion to standard
diameter and 1cu mm extrusion, which caused complications in determining
mm extruded.
chdkActive was set to false regardless of (millis() - chdkHigh) being bigger than the CHDK_DELAY or not. So if (millis() - chdkHigh) wasn't bigger than the delay the first time, the CHDK would never be set back to LOW.
Also, don't return from the function, as there might be other stuff to do, after the CHDK check.
This feature allows the printer to read the filament diameter
automatically and adjust the printer in real time. Added code to read
an analog voltage that represents a filament diameter measurement. This
measurement is delayed in a ring buffer to compensate for sensors that
are a distance away from the extruder. The measurement is used to
adjust the volumetric_multiplier for the extruder. Some additional g
codes (M404, M405, M406, M407) are used to set parameters and turn
on/off the control. g code M221 is updated. Pins for RAMPS1.4, RAMBO,
and Printrboard are identified for analog input. The configuration file
is updated with relevant user parameters.
Positioning of string terminator to truncate checksum from the commands
M23, M28, M30, M32, M928 and M117 was off by one, causing the last
letter of the actual command to be truncated instead of just the
checksum.
In case of the SD commands this caused checksummed commands targeting
existing files to fail since the last letter of the filename was
truncated.
In case of M117 this caused the last given letter not to be displayed.
This patch fixes the off-by-one error and sets the null terminator
on the exact position of the * starting the checksum instead of the
character before that.