427 Commits (8679f671ed678637eb7165f33b37cd7ce8aa242b)

Author SHA1 Message Date
Scott Lahteine 325bbbc8c2
[2.0.x] Enable AD595 and AD8495 in concert (#10693)
* Allow both AD595 and AD8495 in concert
* General temperature code tweaks
7 years ago
Scott Lahteine 23a876b08d Update a comment in motion.cpp 7 years ago
Scott Lahteine 439e0cdd0f
Patch up reverse_pass_kernel (and other planner code) (#10674) 7 years ago
Scott Lahteine 57c2f8d2f6 Trailing whitespace cleanup 7 years ago
Scott Lahteine b76344c080 More Trinamic cleanup 7 years ago
Scott Lahteine 722aba77f3
Fix LIN_ADVANCE + SWITCHING_EXTRUDER stepper directions (#10656) 7 years ago
Scott Lahteine a225d2e99e Fix compilation with UBL and Arc/Bézier
Fix #10660
7 years ago
Scott Lahteine 6d9ec1852a Fix compilation of say_units
Fixes #10663
7 years ago
Scott Lahteine 19f189b4e5
Add UBL support for G2/G3 and G5 (#10648) 7 years ago
Scott Lahteine 4d4bf7897d Junction Deviation jerk limiting option 7 years ago
Scott Lahteine 0436e16fb2 Apply shorthand Assembler macros 7 years ago
Scott Lahteine d1b619be52 Standardize some hexadecimals 7 years ago
Scott Lahteine 55f1f8446b Show correct current units in M503 7 years ago
Scott Lahteine 1f11b0f612 Fully init planner sync block 7 years ago
Scott Lahteine bfe223e120 Adjust usage of stepper.synchronize 7 years ago
Scott Lahteine af1950a63e Improve sync of stepper positions 7 years ago
Scott Lahteine 0c23792344 Apply int32_t to stepper 7 years ago
Scott Lahteine 81b632c255 Additional temp-oriented improvements 7 years ago
nightdemonx e911635fb1 Add thermocouple with AD8495 support 7 years ago
Scott Lahteine d7b699ec34 Fewer includes of vector_3.h 7 years ago
Scott Lahteine 2c1205d8b1 Improve debug of homing move feedrate 7 years ago
Scott Lahteine c8e4b7c8a6 Fix XY homing move away rate 7 years ago
MagoKimbra 1f92b9a4ed Fix do_probe_move with fr_mm_s (#10576) 7 years ago
Scott Lahteine 4dfc011d86 Fix homing with probe feedrates 7 years ago
Scott Lahteine 59fda986ea Allow Z_AFTER_PROBING to be 0 7 years ago
Scott Lahteine 1dab44213a Fix the TMC26X initializer CS pin argument
From #10531

Co-Authored-By: chriscg9 <chriscg9@users.noreply.github.com>
7 years ago
Scott Lahteine 7546f87949 Allow a home bump of 0 when homing Z with probe 7 years ago
Scott Lahteine 683dc24e0f When homing with Z probe bump at Z_PROBE_SPEED_SLOW 7 years ago
Scott Lahteine 5ac226aa93 Further cleanup of inline delays 7 years ago
Chris Pepper 2242b98248 [LPC176x] Emergency Parser Feature (#10516) 7 years ago
Scott Lahteine 9789c1c719 Fix current_temperature_chamber compile error
Fix #10505
7 years ago
Eduardo José Tagle 0c428a66d9 Proper AVR preemptive interrupt handling (#10496)
Also simplify logic on all ARM-based interrupts. Now, it is REQUIRED to properly configure interrupt priority. USART should have highest priority, followed by Stepper, and then all others.
7 years ago
Scott Lahteine f423e54f77 Strip trailing spaces 7 years ago
Scott Lahteine cb46cb8480
Add HAS_HEATED_BED conditional (#10495) 7 years ago
Scott Lahteine a90cbc6339
[2.0.x] Wait for bed heaters between probing (#10472) 7 years ago
Scott Lahteine 5a064d0e94 Fix bug in planner.set_position_mm 7 years ago
Scott Lahteine 8f57e098de Use end-of-line comments in planner.cpp 7 years ago
Scott Lahteine 36b97bde9f clear_block_buffer, kill_current_block in quick_stop 7 years ago
Luc Van Daele 12785583d0 [2.0.x] G33 MIN_STEPS_PER_SEGMENT (#10386) 7 years ago
Luc Van Daele 646aa20b43 Overhaul of G33 Delta Calibration (#8822) 7 years ago
Luc Van Daele ac2e0afb62 Low Point for delta calibration (#10363) 7 years ago
Eduardo José Tagle 57a899a412 [2.0.x] 6th-order jerk-controlled motion planning in real-time for AVR (#10373) 7 years ago
Sean 2d9b0a66fe Add Filament Change accelerations 7 years ago
Scott Lahteine 8b8ad14178 Add Z_PROBE_LOW_POINT to prevent damage 7 years ago
etagle a29adde5c0 Implement BEZIER_JERK_CONTROL
Enable 6th-order jerk-controlled motion planning in real-time.
Only for 32bit MCUs. (AVR simply does not have enough processing power for this!)
7 years ago
Lenbok 0e8242180d Chamber temperature monitoring and auto fan control.
This is an initial cut for feedback, updated for 2.0.x.

Chamber temperature is currently reported along with hot end and bed
temperatures to serial. The format is just like that used for hot end
and bed temperatures, but using 'C' prefix. As there is no heater,
target is always 0. Is this appropriate, is there a better way to report
chamber temperatures?

Chamber temperatures are not reported on the LCD in any way.

When auto chamber fan is enabled, it currently just uses the same
temperature threshold as the other auto controlled fans.

As the chamber temperature is not connected to any heater, it doesn't
undergo mintemp/maxtemp monitoring. This would need to change in the
future if chamber heating became a feature.
7 years ago
Marcio Teixeira 75037493fa Default active low for TMC2130 DIAG1 (#10294)
- Added sanity check to inform users to set the endstop to inverting
  when using SENSORLESS_HOMING
7 years ago
Scott Lahteine e8e60263c8 Scale feedrate (mm/s to deg/s) for SCARA 7 years ago
Scott Lahteine 1c36606886 Fix MSG_HEATING_FAILED_LCD_BED macro evaluation 7 years ago
Scott Lahteine fe91514395
MBL should add z_offset regardless of fade (#10308) 7 years ago