Improvement to avoid reinitializing delay buffer with every print. Fixed
issues in buffer indexing and memory out of bounds due to floating point
imprecision. Simplified the code by avoiding conversion to standard
diameter and 1cu mm extrusion, which caused complications in determining
mm extruded.
chdkActive was set to false regardless of (millis() - chdkHigh) being bigger than the CHDK_DELAY or not. So if (millis() - chdkHigh) wasn't bigger than the delay the first time, the CHDK would never be set back to LOW.
Also, don't return from the function, as there might be other stuff to do, after the CHDK check.
This feature allows the printer to read the filament diameter
automatically and adjust the printer in real time. Added code to read
an analog voltage that represents a filament diameter measurement. This
measurement is delayed in a ring buffer to compensate for sensors that
are a distance away from the extruder. The measurement is used to
adjust the volumetric_multiplier for the extruder. Some additional g
codes (M404, M405, M406, M407) are used to set parameters and turn
on/off the control. g code M221 is updated. Pins for RAMPS1.4, RAMBO,
and Printrboard are identified for analog input. The configuration file
is updated with relevant user parameters.
Positioning of string terminator to truncate checksum from the commands
M23, M28, M30, M32, M928 and M117 was off by one, causing the last
letter of the actual command to be truncated instead of just the
checksum.
In case of the SD commands this caused checksummed commands targeting
existing files to fail since the last letter of the filename was
truncated.
In case of M117 this caused the last given letter not to be displayed.
This patch fixes the off-by-one error and sets the null terminator
on the exact position of the * starting the checksum instead of the
character before that.
FW retraction is extended onto swap retraction invoked by 'G10 S1'.
Bookkeeping of the retract state of all extruders allows for having one
extruder fw standard retracted while another extruder is swap retracted.
An LCD menu item for the swap retract and recover length was added.
some guy find that marlin not working good for dual extruders delta .
when type T0 or T1 to active extruder and E0 or E1 move causing XYZ
motion . so i locales the bugs and fix it , I have dry run the fix.
Firmware retraction now stores the retract and recover speeds in mm/s
instead of mm/min. This makes it match the units of the maximum
feedrate, and fixes problems with modifying the value via LCD control
panel. From gcode, the values are still taken in mm/min to match the
units of G1 and similar, and they are converted to mm/s before they are
stored.
I also lowered the default retract feedrate to make it less likely to
cause problems for geared extruders when the user hasn’t bothered to
set a reasonable maximum feedrate, though users should be setting both
of these values to suit their hardware.
I made these changes previously, but I can’t find the commit now. This
reapplies the changes to get auto retract working again.
Conflicts:
Marlin/Configuration_adv.h
Marlin/Marlin_main.cpp
This should make it safe to enable FWRETRACT by default, with
autoretract (which should now be fixed) only enabled by M209. FWRETRACT
should probably now default to enabled (to make G10/G11 and M207-209
available, without changing functionality when they are not used), but
I’ll save that for another pull request/discussion.
This takes the (now working) G10/G11 code and moves it to a function,
which is called by G10 and G11, and also called by G1 if autoretract is
enabled and a retract/recover move is detected.
Add digipot i2c control for MCP4451
Allow M907 to set i2c digipot currents in amps
Fix Makefile to allow Azteeg motherboards
Fix Makefile to allow Wire libraries only
Add beeper pin for Azteeg X3 Pro