Looks like INVERT_E3_DIR was missing in the configuration.h also as I
did a test compile with 4 extruders and Azteeg X3 Pro defined. So I also
added those lines too. Additional formatting to make the comments line
up better in that section.
Here were a few changes that I had to make/add lines for the 4th hotend.
A compiling problem in the Temperature.cpp and missing lines in
configuration.h and configuration_adv.h. I added these lines in all of
the example configs too.
* Adds config parameter `PID_PARAMS_PER_EXTRUDER` - allows single PID
parameters to be used where this would be preferable (e.g. dual
identical extruders)
* When disabled, will use `float Kp, Ki, Kd, Kc;` as before.
Preprocessor macros used to switch between.
* ultralcd.cpp defines extra menus for extra parameters only where
required
* M301 reports `e:xx` only if independent pid parameters enabled
* EEPROM structure still leaves space for 3 extruders worth, when undef
will save single parameter to all extruder positions, but only read the
first
* Switching off saves approx 330 B with no LCD enabled, 2634B with LCD
(RRD) enabled: this is significant.
* LCD modifications should be tested.
* Variables Kp, Ki, Kd, Kc now arrays of size EXTRUDERS
* M301 gains (optional, default=0) E parameter to define which
extruder's settings to modify. Tested, works with Repetier Host's EEPROM
config window, albeit only reads/updates settings for E0.
* All Kp, Ki, Kd, Kc parameters saved in EEPROM (version now v14), up to
3 extruders supported (same as Marlin in general)
Improvement to avoid reinitializing delay buffer with every print. Fixed
issues in buffer indexing and memory out of bounds due to floating point
imprecision. Simplified the code by avoiding conversion to standard
diameter and 1cu mm extrusion, which caused complications in determining
mm extruded.
This feature allows the printer to read the filament diameter
automatically and adjust the printer in real time. Added code to read
an analog voltage that represents a filament diameter measurement. This
measurement is delayed in a ring buffer to compensate for sensors that
are a distance away from the extruder. The measurement is used to
adjust the volumetric_multiplier for the extruder. Some additional g
codes (M404, M405, M406, M407) are used to set parameters and turn
on/off the control. g code M221 is updated. Pins for RAMPS1.4, RAMBO,
and Printrboard are identified for analog input. The configuration file
is updated with relevant user parameters.
This is a feature to protect your printer from burn up in flames if it
has a thermistor coming off place (this happened to a friend of mine
recently and motivated me writing this feature).
The issue: If a thermistor come off, it will read a lower temperature
than actual. The system will turn the heater on forever, burning up the
filament and anything
else around.
After the temperature reaches the target for the first time, this
feature will start measuring for how long the current temperature stays
below the target minus _HYSTERESIS (set_temperature -
THERMAL_RUNAWAY_PROTECTION_HYSTERESIS).
If it stays longer than _PERIOD, it means the thermistor temperature
cannot catch up with the target, so something *may be* wrong. Then, to
be on the safe side, the system will he halt.
Bear in mind the count down will just start AFTER the first time the
thermistor temperature is over the target, so you will have no problem
if your extruder heater takes 2 minutes to hit the target on heating.
Users can be confused as to which values to enter after a PID tune. Updating the message to help clarity it.
New message: "PID Autotune finished! Put the last Kp, Ki and Kd constants from above into Configuration.h"
Old message: "PID Autotune finished! Put the Kp, Ki and Kd constants into Configuration.h"
In some cases the Bed Heater FET heats up more then stepper drivers, so
this change add the bed monitoring to the controller fan. As soon as the
bed heater is turned on, the controller fan will run as well.