868 Commits (5f8e52aefb62035158fb667eb2ac2efb02032b39)

Author SHA1 Message Date
Scott Lahteine e8fa843c2d Merge pull request #3164 from epatel/epatel/RCBugFix
Fix for #3160 MESH_BED_LEVELING broke correct G1 movement in Z
9 years ago
Scott Lahteine d7c6fd5c2f Merge pull request #3146 from thinkyhead/rc_enabled_true_false
Support "true" and "false" in the ENABLED macro
9 years ago
Edward Patel cb0dbfa3b5 Fix for #3160 MESH_BED_LEVELING broke correct G1 movement in Z 9 years ago
Scott Lahteine 6e1bc03d3b Additional wrapping for #3140 9 years ago
Scott Lahteine 1c384930f3 Merge pull request #3140 from thinkyhead/rc_fix_macro_expansion
Wrap macros to prevent bad expansions
9 years ago
esenapaj a4314c4907 Use local variable in recalc_delta_settings()
diagonal_rod hadn't been used anywhere.
9 years ago
esenapaj 8de7a6f9b1 suppress warnings 9 years ago
Scott Lahteine 4b648793f2 Use ENABLED with DISABLE_[INACTIVE_][XYZ] 9 years ago
Scott Lahteine 3f5fbbd398 Merge pull request #3124 from jbrazio/bugfix/update-g29-auto-level-bed-topography
Update the bed topography output done by G29
9 years ago
Scott Lahteine f9ded2a7c4 Wrap macros to prevent bad expansions 9 years ago
jbrazio a645860431 All print timer related activity now uses print_job_start(), print_job_timer() or print_job_stop() 9 years ago
jbrazio 1981e53d68 M109 R option if misused could cause a wait-forever situation 9 years ago
João Brázio 4d4a842cfb Update the bed topography output done by G29 9 years ago
João Brázio 793cd0ae3b Clean up the code a bit 9 years ago
jbrazio 986b508ff7 Print timer now stops when it sees the last extruder temperature being shutdown 9 years ago
AnHardt fd5414c6ea Z_RAISE_BEFORE_HOMING -> MIN_Z_HEIGHT_FOR_HOMING
rebased
corrected spelling
changed to #elif for error

Still with MIN_Z_HEIGHT_FOR_HOMING but con be done with (folder wide) search-replace when we have a better name.
9 years ago
Scott Lahteine b7928a000a Merge pull request #3108 from AnHardt/M110+
M110 and M29 rework
9 years ago
Scott Lahteine 5cba0b4187 Merge pull request #3111 from thinkyhead/rc_drop_old_condition
Drop obsolete test for leading "N"
9 years ago
Scott Lahteine 302d1bfbc4 Drop obsolete test for leading "N" 9 years ago
AnHardt 37b857e8ec M110 ang M29 rework
Add 'ok' output for G29 actually closing the file.
Handle M110 when received without linenumber/checksumm.
9 years ago
Scott Lahteine fac85f6fa1 Merge pull request #3102 from jbrazio/bugfix-g28-multiple-z-movements
Bugfix: G28 was lifting Z-axis multiple times
9 years ago
jbrazio 642e3699ce Z-axis was being lift multiple times if Z_SAFE_HOMING was enabled and Z_RAISE_BEFORE_HOMING was greater than zero 9 years ago
Scott Lahteine 501f63802a Merge pull request #3077 from Blue-Marlin/watchdogreset-in-kill
Add Watchdog timer reset in kill()
9 years ago
Scott Lahteine ef68c1910c Check that the temperature is close to target 9 years ago
Scott Lahteine ea9fd1200b Fix M109 so it won't wait for cooling
Addressing issue #2767
9 years ago
Scott Lahteine ff13070b59 Use _BV macros, patch up others 9 years ago
Scott Lahteine 209f5f21e0 Use macros where possible
Apply `constrain`, `NOMORE`, `NOLESS` and `CRITICAL_SECTION` macros
wherever possible.
9 years ago
Scott Lahteine 6e64895c30 Merge pull request #3001 from AlwaysTinkering/RCBugFix
Rc bug fix - Fix for issue #2931
9 years ago
Scott Lahteine 34b8b9f0f5 Merge pull request #2995 from thinkyhead/rcbugfix_corexy_corexz
Add CORE support to st_get_position_mm (and elsewhere)
9 years ago
Scott Lahteine 3a3d358df9 Fix Printrboard with LCD (redo)
Based on #2860 - rebased for RCBugFix
9 years ago
Scott Lahteine eb85342fd9 Merge pull request #2989 from AnHardt/fix2661
Pre home display - Stepper release
9 years ago
Scott Lahteine 14f3ca1b2e Merge pull request #2978 from thinkyhead/tool_offset_abl_rcbugfix
Apply bed leveling matrix when switching extruders
9 years ago
lrpirlet 0fb507a75d correct raise_z_for_servo 9 years ago
Blue-Marlin b4e5e0f11d Add Watchdog reset in kill()
Add watchdog reset in the kill loop to simplify recovering.
9 years ago
Scott Lahteine 222d13d5ed Merge pull request #3051 from thinkyhead/rcbugfix_dual_axis_offset
Code cleanup in gcode_T
9 years ago
Scott Lahteine 186629aee8 Merge pull request #3057 from jbrazio/3034-z_raise_after_probing_fix
Fix Z_RAISE_AFTER_PROBING for non DELTA printers
9 years ago
jbrazio 67e15aac3d As pointed out by @Blue-Marlin the previous code would raise the Z axis
twice for a servo based probe.
9 years ago
jbrazio 17cc2a9663 Z_RAISE_AFTER_PROBING value was being ignored by Marlin because
raise_z_after_probing() was only called if the printer type was set to a
DELTA or if the printer had a docking sled for the probe.
9 years ago
AnHardt 1c889cd303 Refresh previous_cmd_ms during run_z_probe()
Refresh previous_cmd_ms during run_z_probe() to prevent:
stepper shutdown for expired DEFAULT_STEPPER_DEACTIVE_TIME
and extrudes for expired EXTRUDER_RUNOUT_SECONDS
(https://github.com/MarlinFirmware/MarlinDev/issues/238)
9 years ago
AnHardt 4b02f33e69 Distribute config-changes to the other configurations 9 years ago
AnHardt 32ae9f9ab7 Fix stepper shutdown during waiting for temperatures
In the wait loops of M109 M190 idle() is called, what checks
stepper_inactive_time against previous_cmd_ms.
Because we can be several minutes inside the loop, resetting
previous_cmd_ms only outside the loop caused stepper shutdowns.

The name of previous_cmd_ms does not really reflect its use. It's set
not only when a new command was received or executed but also in many of
the movement routines. For that the little extension of using it during
the wait will (hopefully) not hurt.

# Conflicts:
#	Marlin/Configuration_adv.h
9 years ago
AnHardt b6e69e71ce Make stepper shutdown after inactivity dependent
Make stepper shutdown after inactivity dependent on a new set of
#defines.
DISABLE_INACTIV_X
DISABLE_INACTIV_Y
DISABLE_INACTIV_Z
DISABLE_INACTIV_E

And make exemplaric Configuration.
Names can be discussed.

This makes the disabling of the steppers independent from the DISABLE_?
settings witch shut down the steppers immediately.
9 years ago
AnHardt 051325ccd7 Introduce axis_homed
Introduce additional variable axis_homed to replace axix_known_position
when the coordinate display should indicate the axis is not homed.
This is to distinguish between "not homed" and "inexact position possible
because stepper was disabled".

# Conflicts:
#	Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
9 years ago
Scott Lahteine 100271e6ac minor cleanup in gcode_T 9 years ago
Scott Lahteine 6a4f06d35d Fix GCode handling of spaces between command letter and first digit 9 years ago
CONSULitAS ea8409ad5d Fix: current_command_args contains command
@thinkyhead
Hi Scott,
your code from a0f362c@thinkyhead is great, but you forgot to skip the
command.
Symptom `M117 Test`shows `M117 Test` on LCD instead of `Test`.

see also
https://github.com/MarlinFirmware/Marlin/commit/a0f362c735401ebbcd95de3f
6f8e3c2f17ecc770 lines 941, 2851 and so on

Greetings and welcome back

Jochen
9 years ago
Scott Lahteine e1beaf61eb Merge pull request #2985 from AnHardt/adv-ok
Repair N in ADVANCED_OK
9 years ago
Scott Lahteine 0c9db67273 Merge pull request #2983 from AnHardt/ok-echo
Replace the "ok" in M280, M301, M304, M851 with output not including …
9 years ago
Scott Lahteine 8eaba020fb Merge pull request #2973 from thinkyhead/fix_splash_url
Remove references to marlinfirmware.org
9 years ago
Scott Lahteine be691b51f1 Remove references to marlinfirmware.org
The domain is gone and doesn’t redirect, so for now show no URL on the boot screen.
9 years ago
Scott Lahteine 83ffc9eb4f Show raw steps in M114
This is a proposed change. This section of M114 output is a debug
extension according to RepRap wiki.
9 years ago
Scott Lahteine 373e8a1ad4 Fixes for COREXY and COREXZ coordinates 9 years ago
unknown 31656e68bc Fix for homing X and Y before raising Z when Z_SAFE_HOMING is set. 9 years ago
unknown 8ea55323d8 Fix for not raising Z before homing X and Y 9 years ago
Scott Lahteine 711e5db19a Tweak comment in process_next_command 9 years ago
Scott Lahteine 400e9329be Allow spaces after a code letter 9 years ago
Scott Lahteine cdcb80f3c5 Allow no-space after initial command
Addresses issue #2715
9 years ago
AnHardt 6f473f7fc6 Repair N in ADVANCED_OK
Send the correct line number.
If no N was in the command - non't send an N.
9 years ago
AnHardt efbd705eda Replace the "ok" in M280, M301, M304, M851 with output not including an "ok"
Replace the "ok" in M280, M301, M304, M851 with output not including an "ok"
to avoid senting two "ok"s for a single g-code.

Doing the same for M105 would break the input filters of the hosts.
For M105 the other "ok" is omitted.
9 years ago
Scott Lahteine 8e66028d25 Apply the ABL rotation matrix to the extruder offset. 9 years ago
Richard Wackerbarth f6950acb8e Residual unused variable — Backport 9 years ago
AnHardt 57da1b8497 Host parseble output for M109, M190 and M303
Make the output of M105 more similar to Repetier.
Make the text-print pert of M105 an extra function to make it reusable. `print_heaterstates()`
Use `print_heaterstates()` in M019, M190 and M303
9 years ago
AnHardt fcceb98191 Unglobalize no_wait_for_cooling 9 years ago
Richard Wackerbarth e293ea57f0 Unbalanced brackets in setPwmFrequency
This is a back port of the correct in issue #248
9 years ago
Scott Lahteine 17c23bbaf3 Shorten gcode_M221 yet function the same 9 years ago
Scott Lahteine c0e791dbe9 Only look for "N" line number as first parameter 9 years ago
Scott Lahteine b4af4441c5 Clean up watchdog impl. 9 years ago
Scott Lahteine 9bdab4f3a8 Clean up "else" and other spacing 9 years ago
Richard Wackerbarth 25d636c9e0 Compiler issues (PR#2696) 9 years ago
Scott Lahteine ba6a243197 DEBUG message has no parameter (PR#2671) 9 years ago
Scott Lahteine 0c7f7ebcfb Styling adjustments (PR#2668 & PR#2670)
Keep "astyled" reformatting
9 years ago
fmalpartida 0f149ea0c6 LCD home button causes repeated homing (PR#175)
Fix: increased debounce delay.
9 years ago
Scott Lahteine b825567e0f Drop www. from marlinfirmware.org (PR#175) 9 years ago
Scott Lahteine bc50db9cf6 Implement PID_ADD_EXTRUSION_RATE 9 years ago
Scott Lahteine fabf3ae4a0 Add final Z raise after Delta probe 9 years ago
Shane Francis 4c8330c15c Trim Adjustments for Delta Configurations 9 years ago
Scott Lahteine 962120d1d2 Fix spacing in some conditional blocks 9 years ago
Richard Wackerbarth 20b4772155 Create DEBUG_LEVELING_FEATURE 9 years ago
Scott Lahteine 194f98ff95 Debug messages for homing and leveling 9 years ago
Richard Wackerbarth 6292d9e815 Rename ENABLE_AUTO_BED_LEVELING
With the introduction of the #if ENABLED(…)

reads better than
9 years ago
Christian Lefrançois 9897a9147c Update ABL comments (PR#95)
* Updates the auto bed leveling comments ONLY.
* Renames "Z probe" word usage in //comments and #errors properly.
9 years ago
Scott Lahteine 23d742bf06 Don't free the stack array plane_equation_coefficients (PR#83) 9 years ago
Scott Lahteine e3b1e08777 Patch G30 to use raise_z_for_servo (PR#73) 9 years ago
Scott Lahteine a1eb90d5c0 Save another 30 bytes in gcode_SET_Z_PROBE_OFFSET 10 years ago
Scott Lahteine 91122277f4 Reduce gcode_SET_Z_PROBE_OFFSET by 88 bytes 10 years ago
AnHardt 5707a2c3d5 indexindexIntoAB is only vald for !DELTA 10 years ago
AnHardt d8860f9ad9 Alway end at the same point
Always end at [RIGHT_PROBE_BED_POSITION, BACK_PROBE_BED_POSITION]
Regardles the evennes of auto_bed_leveling_grid_points.
10 years ago
AnHardt 4ca8f4a9a7 Always zigzag
Use the shortest way between probing-points.
10 years ago
AnHardt 3d23424121 Add array indexIntoAB[xx][yy]
and use it.
10 years ago
AnHardt e2d69f66b2 Make Z_PROBE a Z_MIN_PROBE (PR#65)
Currently we use the probe exclusively as a device to find the build platform(bed).
For the currently supported setups this means, we use it as a additional min-endstop.
A triggered when not deployed probe disturbs the homing process for max-endstops.

Rename ENDSTOPPULLUP_ZPROBE to ENDSTOPPULLUP_ZMIN_PROBE
Rename Z_PROBE_ENDSTOP_INVERTING to Z_MIN_PROBE_ENDSTOP_INVERTING
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Rename DISABLE_Z_PROBE_ENDSTOP to DISABLE_Z_MIN_PROBE_ENDSTOP
Rename Z_PROBE_REPEATABILITY_TEST to Z_MIN_PROBE_REPEATABILITY_TEST
Rename Z_PROBE_ENDSTOP to Z_MIN_PROBE_ENDSTOP
Adjust comments accordingly
Remove Z_MAX  check for the probe in update_endstops().

Using an delta related idea of @clefranc from #61,
extended to the general change for all setups.

Tested with Prusa i3, max-z-endstop and permanently triggered z-probe.
Worked for @clefranc's delta.
10 years ago
Richard Wackerbarth 9d8cc24abf Continue from the line following the M999 (PR#60)
If the printer is going to accept the M999,
then it should continue from that line number.
10 years ago
Scott Lahteine 46453905d6 Apply remaining ENABLED/DISABLED conditionals 10 years ago
Richard Wackerbarth b227d8c128 Supply a VERSION in a short form for displays
The long descriptor will still be available in M115
10 years ago
AnHardt 4f46df5dab Make bootscreen configurable for the graphic displays
Saves about 473 byte of progmem and 28 bytes of RAM.
10 years ago
Scott Lahteine b4abb0ae7f Apply ENABLED / DISABLED to Marlin core files (PR#2558) 10 years ago
Scott Lahteine 9d151bb61b servo_endstop_angles -> servo_endstop_angle 10 years ago
Scott Lahteine 1f63293624 servo_endstops -> servo_endstop_id 10 years ago
Scott Lahteine ed4a6371ad Add HAS_SERVO_ENDSTOPS to simplify conditonals 10 years ago
Scott Lahteine ae9274be05 Fix minor compiler warnings in for loops 10 years ago
Scott Lahteine 4a58e447a1 Add array size to servo_endstop_angles (PR#2553) 10 years ago