Follow-up the PR #3643(Temperature singleton)
・Change from fanSpeedSoftPwm[0] to thermalManager.fanSpeedSoftPwm[0] in planner.cpp
It fix compilation error when FAN_SOFT_PWM is enabled.
・Remove declaration of setExtruderAutoFanState() in temperature.h
Because that function was abolished.
・Change from babystepsTodo to thermalManager.babystepsTodo in ultralcd.cpp
It fix compilation errors when BABYSTEPPING is enabled.
When setting the bed temp via M140/M190 if the thermistor does not read an increase of WATCH_BED_TEMP_INCREASE degrees by WATCH_BED_TEMP_PERIOD seconds then it will throw "Error:Heating failed, system stopped! Heater_ID: bed" and call the kill() function.
Conflicts:
Marlin/Configuration_adv.h
to warrant watching is set or reset.
Make setTargetBed() in _lcd_preheat() dependant of TEMP_SENSOR_BED.
Use disable_all_heaters() in lcd_cooldown() and abort_on_endstop_hit.
- Make thermal protection for all hotends and/or bed into simple
switches
- Now enable `WATCH_TEMP_PERIOD` when `THERMAL_PROTECTION_HOTENDS` is
enabled
- Move detailed thermal parameters to `Configuration_adv.h`
- Add sanity checks to warn about old configurations
- Change `WATCH_TEMP_PERIOD` to seconds instead of milliseconds
- Add comments documenting `thermal_runaway_protection`
- Add an enum for the thermal runaway states
- Add macros for temperature helper functions
- Fix a glitch with the z probe sled in homeaxis
cardreader.cpp needs temperature.h for autotempShutdown() when
AUTOTEMP is defined but warns about unused variables.
Unpublished variables by putting them in to temperature.cpp.
- Reduce calls to millis()
- General cleanup of manage_heaters
- General cleanup of pid autotune
- Formatting here & there
- Macros to clean up and shrink ISR code (reduced by ~364 lines)
* Adds config parameter `PID_PARAMS_PER_EXTRUDER` - allows single PID
parameters to be used where this would be preferable (e.g. dual
identical extruders)
* When disabled, will use `float Kp, Ki, Kd, Kc;` as before.
Preprocessor macros used to switch between.
* ultralcd.cpp defines extra menus for extra parameters only where
required
* M301 reports `e:xx` only if independent pid parameters enabled
* EEPROM structure still leaves space for 3 extruders worth, when undef
will save single parameter to all extruder positions, but only read the
first
* Switching off saves approx 330 B with no LCD enabled, 2634B with LCD
(RRD) enabled: this is significant.
* LCD modifications should be tested.
* Variables Kp, Ki, Kd, Kc now arrays of size EXTRUDERS
* M301 gains (optional, default=0) E parameter to define which
extruder's settings to modify. Tested, works with Repetier Host's EEPROM
config window, albeit only reads/updates settings for E0.
* All Kp, Ki, Kd, Kc parameters saved in EEPROM (version now v14), up to
3 extruders supported (same as Marlin in general)
This feature allows the printer to read the filament diameter
automatically and adjust the printer in real time. Added code to read
an analog voltage that represents a filament diameter measurement. This
measurement is delayed in a ring buffer to compensate for sensors that
are a distance away from the extruder. The measurement is used to
adjust the volumetric_multiplier for the extruder. Some additional g
codes (M404, M405, M406, M407) are used to set parameters and turn
on/off the control. g code M221 is updated. Pins for RAMPS1.4, RAMBO,
and Printrboard are identified for analog input. The configuration file
is updated with relevant user parameters.
This is a feature to protect your printer from burn up in flames if it
has a thermistor coming off place (this happened to a friend of mine
recently and motivated me writing this feature).
The issue: If a thermistor come off, it will read a lower temperature
than actual. The system will turn the heater on forever, burning up the
filament and anything
else around.
After the temperature reaches the target for the first time, this
feature will start measuring for how long the current temperature stays
below the target minus _HYSTERESIS (set_temperature -
THERMAL_RUNAWAY_PROTECTION_HYSTERESIS).
If it stays longer than _PERIOD, it means the thermistor temperature
cannot catch up with the target, so something *may be* wrong. Then, to
be on the safe side, the system will he halt.
Bear in mind the count down will just start AFTER the first time the
thermistor temperature is over the target, so you will have no problem
if your extruder heater takes 2 minutes to hit the target on heating.
In some cases the Bed Heater FET heats up more then stepper drivers, so
this change add the bed monitoring to the controller fan. As soon as the
bed heater is turned on, the controller fan will run as well.