Right now G26 doesn't send a notice to the host that it's running. It's
not until the heaters are at temperature that you know for sure if it's
running or not.
Added host temperature prints so that someone watching the host
interface will see the temperatures change during the warm up period.
Updates are sent every 5 seconds.
* Correct over optimization of pre-initialized variables
NEAR_ZERO() works most of the time... But it leaves corner cases
uncovered. We need to explicitly check if these variables are +/-
infinity.
* Correct over optimization of pre-initialized variables
This is what I did yesterday:
- basicly gave the tests more comprehensive names; put all the
declarations at the top; got rid of the magic negative C-value (renamed
to P + A, O, T)
- "cos(RADIANS(180 + 30 * axis)) * (1 + circles * 0.1 * ((zig_zag) ? 1 :
-1)) * delta_calibration_radius" compiles wrong is zig_zag statement is
without brackets
- DELTA_TOWER_ANGLE_TRIM reset to 3 values (the calcs use the 3th value
to normalize will not compile otherwise)
-Wrote 3 dummies to keep EEPROM lenght the same
-Reset the configs to the 'original' with autocal + menu disabled (but
can be enabled of course)
The Configuration.h file entries for BL-Touch have been updated to:
```cpp
//#define BLTOUCH
//#define BLTOUCH_DELAY 375 // (ms) Enable and increase if needed
//#define BLTOUCH_HEATERS_OFF // if defined the printer's heaters are
turned off during probe event
```
The electro-magnetic interference from the bed and nozzle are affecting
the BL-Touch repeatability for some users. This problem can be helped
by shutting down the heaters during the actual probe event and then
quickly turning them back on.
Because this code is messing with the heaters, it is written in a
paranoid manner. It only turns the heaters back on if everything is
EXACTLY as it expects things to be. The BL-Touch probe must have been
put into a deployed state less than 20 seconds prior, or the stow()
function will NOT turn the heaters on.
This code has been tested and works for both G28 and probing functions.
Giving a negative number of probe points disables the tower angle
correction calibration ('4point' instead of '7point' solution)
EEPROM version updated
These are my two 'Nice' machines. Both are good example machines. The
FolgerTech i3-2020 is probably the best value kit on the market right
now. And it has developed a 'Cult Following' of hobbiests. I'll always
have an up to date Configuration.h file set for it, so it may as well be
an example configuration.
And the gCreate gMax 1.5+ is the best printer I've ever seen that runs
Marlin. For sure, I'll always have up to the minute Configuration.h
files for this printer also. I've moved over to using the gMax as my
primary development machine for Marlin. So... Besides being a good
machine, it is a nice convienience for me to have this Configuration.h
file as an 'Example'.
Also... The memory corruption issue may be fixed. The GCC compiler
was inlining static functions and this caused the G29() stack frame to
become much larger than the AVR could handle.
* relocated ubl state to config. store:
* removed a number of ubl state variables and padding which were largely unused - saved 58 bytes of both SRAM and EEPROM;
* modified ubl sanity_check - no longer checks removed state variables that were otherwise unused, where checking didn't seem to accomplish anything, ultimately;
* removed pre_initialized state, saving 64 bytes of SRAM;
* removed automatic saving of UBL state after UBL activation/deactivation;
* consolidated multiple GRID_MAX_POINTS_X/Y to 'Global Leveling' section of EEPROM;
* minor update to G29 Sx notes/instructions;
* renamed mesh load and save parameter to 'slot' from 'm' for clarity;
- Making M665 compatible with repetier (see
http://reprap.org/wiki/G_code#M665:_Set_delta_configuration)
- M665 B also sets the radius for manual calibration menu
- Converting tower ajustment definitions to arrays - tower angle
corrections compatible with Esher 3D wizzard
- Only tower angles need to be adjustable with M665 and stored to EEPROM
- tower radius and diag rod can be adjusted in the FW only with #define