@ -1258,11 +1258,11 @@
|
|
|
|
|
#define E5_HYBRID_THRESHOLD 30
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|
* Use stallGuard2 to sense an obstacle and trigger an endstop.
|
|
|
|
|
* You need to place a wire from the driver's DIAG1 pin to the X/Y endstop pin.
|
|
|
|
|
* Use StallGuard2 to sense an obstacle and trigger an endstop.
|
|
|
|
|
* Connect the stepper driver's DIAG1 pin to the X/Y endstop pin.
|
|
|
|
|
* X, Y, and Z homing will always be done in spreadCycle mode.
|
|
|
|
|
*
|
|
|
|
|
* X/Y/Z_HOMING_SENSITIVITY is used for tuning the trigger sensitivity.
|
|
|
|
|
* X/Y/Z_STALL_SENSITIVITY is used for tuning the trigger sensitivity.
|
|
|
|
|
* Higher values make the system LESS sensitive.
|
|
|
|
|
* Lower value make the system MORE sensitive.
|
|
|
|
|
* Too low values can lead to false positives, while too high values will collide the axis without triggering.
|
|
|
|
@ -1271,10 +1271,18 @@
|
|
|
|
|
*/
|
|
|
|
|
//#define SENSORLESS_HOMING // TMC2130 only
|
|
|
|
|
|
|
|
|
|
#if ENABLED(SENSORLESS_HOMING)
|
|
|
|
|
#define X_HOMING_SENSITIVITY 8
|
|
|
|
|
#define Y_HOMING_SENSITIVITY 8
|
|
|
|
|
//#define Z_HOMING_SENSITIVITY 8
|
|
|
|
|
/**
|
|
|
|
|
* Use StallGuard2 to probe the bed with the nozzle.
|
|
|
|
|
*
|
|
|
|
|
* CAUTION: This could cause damage to machines that use a lead screw or threaded rod
|
|
|
|
|
* to move the Z axis. Take extreme care when attempting to enable this feature.
|
|
|
|
|
*/
|
|
|
|
|
//#define SENSORLESS_PROBING // TMC2130 only
|
|
|
|
|
|
|
|
|
|
#if ENABLED(SENSORLESS_HOMING) || ENABLED(SENSORLESS_PROBING)
|
|
|
|
|
#define X_STALL_SENSITIVITY 8
|
|
|
|
|
#define Y_STALL_SENSITIVITY 8
|
|
|
|
|
//#define Z_STALL_SENSITIVITY 8
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|