Low Point for delta calibration (#10363)

2.0.x
Luc Van Daele 7 years ago committed by Scott Lahteine
parent 57a899a412
commit ac2e0afb62

@ -137,7 +137,7 @@ static void G33_cleanup(
inline float calibration_probe(const float nx, const float ny, const bool stow) {
#if HAS_BED_PROBE
return probe_pt(nx, ny, stow ? PROBE_PT_STOW : PROBE_PT_RAISE, 0, true);
return probe_pt(nx, ny, stow ? PROBE_PT_STOW : PROBE_PT_RAISE, 0, false);
#else
UNUSED(stow);
return lcd_probe_pt(nx, ny);

@ -539,28 +539,15 @@ static bool do_probe_move(const float z, const float fr_mm_m) {
*
* @return The raw Z position where the probe was triggered
*/
#define HAS_CALIBRATION_PROBE (ENABLED(DELTA_AUTO_CALIBRATION) && Z_PROBE_LOW_POINT < 0)
static float run_z_probe(
#if HAS_CALIBRATION_PROBE
const bool is_calibration
#endif
) {
static float run_z_probe() {
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) DEBUG_POS(">>> run_z_probe", current_position);
#endif
#if Z_PROBE_LOW_POINT < 0
// Stop the probe before it goes too low to prevent damage.
// If Z isn't known or this is a "calibration probe" then probe to -10mm.
#if !HAS_CALIBRATION_PROBE
constexpr bool is_calibration = false;
#endif
const float z_probe_low_point = !is_calibration && axis_known_position[Z_AXIS] ? -zprobe_zoffset + Z_PROBE_LOW_POINT : -10.0;
#else
// Assertively move down in all cases
constexpr float z_probe_low_point = -10.0;
#endif
// If Z isn't known then probe to -10mm.
const float z_probe_low_point = axis_known_position[Z_AXIS] ? -zprobe_zoffset + Z_PROBE_LOW_POINT : -10.0;
// Double-probing does a fast probe followed by a slow probe
#if MULTIPLE_PROBING == 2
@ -645,14 +632,14 @@ static float run_z_probe(
* - Raise to the BETWEEN height
* - Return the probed Z position
*/
float probe_pt(const float &rx, const float &ry, const ProbePtRaise raise_after/*=PROBE_PT_NONE*/, const uint8_t verbose_level/*=0*/, const bool is_calibration/*=false*/) {
float probe_pt(const float &rx, const float &ry, const ProbePtRaise raise_after/*=PROBE_PT_NONE*/, const uint8_t verbose_level/*=0*/, const bool probe_relative/*=true*/) {
#if ENABLED(DEBUG_LEVELING_FEATURE)
if (DEBUGGING(LEVELING)) {
SERIAL_ECHOPAIR(">>> probe_pt(", LOGICAL_X_POSITION(rx));
SERIAL_ECHOPAIR(", ", LOGICAL_Y_POSITION(ry));
SERIAL_ECHOPAIR(", ", raise_after == PROBE_PT_RAISE ? "raise" : raise_after == PROBE_PT_STOW ? "stow" : "none");
SERIAL_ECHOPAIR(", ", int(verbose_level));
SERIAL_ECHOPAIR(", ", is_calibration ? "nozzle" : "probe");
SERIAL_ECHOPAIR(", ", probe_relative ? "probe" : "nozzle");
SERIAL_ECHOLNPGM("_relative)");
DEBUG_POS("", current_position);
}
@ -660,7 +647,7 @@ float probe_pt(const float &rx, const float &ry, const ProbePtRaise raise_after/
// TODO: Adapt for SCARA, where the offset rotates
float nx = rx, ny = ry;
if (!is_calibration) {
if (probe_relative) {
if (!position_is_reachable_by_probe(rx, ry)) return NAN; // The given position is in terms of the probe
nx -= (X_PROBE_OFFSET_FROM_EXTRUDER); // Get the nozzle position
ny -= (Y_PROBE_OFFSET_FROM_EXTRUDER);
@ -684,11 +671,7 @@ float probe_pt(const float &rx, const float &ry, const ProbePtRaise raise_after/
float measured_z = NAN;
if (!DEPLOY_PROBE()) {
measured_z = run_z_probe(
#if HAS_CALIBRATION_PROBE
is_calibration
#endif
) + zprobe_zoffset;
measured_z = run_z_probe() + zprobe_zoffset;
if (raise_after == PROBE_PT_RAISE)
do_blocking_move_to_z(current_position[Z_AXIS] + Z_CLEARANCE_BETWEEN_PROBES, MMM_TO_MMS(Z_PROBE_SPEED_FAST));

@ -40,7 +40,7 @@
PROBE_PT_STOW, // Do a complete stow after run_z_probe
PROBE_PT_RAISE // Raise to "between" clearance after run_z_probe
};
float probe_pt(const float &rx, const float &ry, const ProbePtRaise raise_after=PROBE_PT_NONE, const uint8_t verbose_level=0, const bool is_calibration=false);
float probe_pt(const float &rx, const float &ry, const ProbePtRaise raise_after=PROBE_PT_NONE, const uint8_t verbose_level=0, const bool probe_relative=true);
#define DEPLOY_PROBE() set_probe_deployed(true)
#define STOW_PROBE() set_probe_deployed(false)
#else

Loading…
Cancel
Save