Apply M600 updates to all configs

2.0.x
Scott Lahteine 8 years ago
parent 8bf0b496b9
commit 931914e679

@ -695,33 +695,42 @@
#define RETRACT_RECOVER_FEEDRATE 8 //default feedrate for recovering from retraction (mm/s) #define RETRACT_RECOVER_FEEDRATE 8 //default feedrate for recovering from retraction (mm/s)
#endif #endif
// Add support for experimental filament exchange support M600; requires display /**
#if ENABLED(ULTIPANEL) * Filament Change
// #define FILAMENT_CHANGE_FEATURE // Enable filament exchange menu and M600 g-code (used for runout sensor too) * Experimental filament change support.
#if ENABLED(FILAMENT_CHANGE_FEATURE) * Adds the GCode M600 for initiating filament change.
#define FILAMENT_CHANGE_X_POS 30 // X position of hotend *
#define FILAMENT_CHANGE_Y_POS 10 // Y position of hotend * Requires an LCD display.
#define FILAMENT_CHANGE_Z_ADD 10 // Z addition of hotend (lift) * This feature is required for the default FILAMENT_RUNOUT_SCRIPT.
#define FILAMENT_CHANGE_XY_FEEDRATE 100 // X and Y axes feedrate in mm/s (also used for delta printers Z axis) */
#define FILAMENT_CHANGE_Z_FEEDRATE 5 // Z axis feedrate in mm/s (not used for delta printers) //#define FILAMENT_CHANGE_FEATURE
#define FILAMENT_CHANGE_RETRACT_LENGTH 1 // Initial retract in mm #if ENABLED(FILAMENT_CHANGE_FEATURE)
// It is a short retract used immediately after print interrupt before move to filament exchange position #define FILAMENT_CHANGE_X_POS 30 // X position of hotend
#define FILAMENT_CHANGE_RETRACT_FEEDRATE 60 // Initial retract feedrate in mm/s #define FILAMENT_CHANGE_Y_POS 10 // Y position of hotend
//#define FILAMENT_CHANGE_UNLOAD_LENGTH 100 // Unload filament length from hotend in mm #define FILAMENT_CHANGE_Z_ADD 10 // Z addition of hotend (lift)
// Longer length for bowden printers to unload filament from whole bowden tube, #define FILAMENT_CHANGE_XY_FEEDRATE 100 // X and Y axes feedrate in mm/s (also used for delta printers Z axis)
// shorter lenght for printers without bowden to unload filament from extruder only, #define FILAMENT_CHANGE_Z_FEEDRATE 5 // Z axis feedrate in mm/s (not used for delta printers)
// 0 to disable unloading for manual unloading #define FILAMENT_CHANGE_RETRACT_LENGTH 1 // Initial retract in mm
#define FILAMENT_CHANGE_UNLOAD_FEEDRATE 10 // Unload filament feedrate in mm/s - filament unloading can be fast // It is a short retract used immediately after print interrupt before move to filament exchange position
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_RETRACT_FEEDRATE 60 // Initial retract feedrate in mm/s
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, //#define FILAMENT_CHANGE_UNLOAD_LENGTH 100 // Unload filament length from hotend in mm
// Short or zero length for printers without bowden where loading is not used // Longer length for bowden printers to unload filament from whole bowden tube,
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast // shorter lenght for printers without bowden to unload filament from extruder only,
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, // 0 to disable unloading for manual unloading
// 0 to disable for manual extrusion #define FILAMENT_CHANGE_UNLOAD_FEEDRATE 10 // Unload filament feedrate in mm/s - filament unloading can be fast
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// or until outcoming filament color is not clear for filament color change // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate // Short or zero length for printers without bowden where loading is not used
#endif #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -721,12 +721,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -721,12 +721,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -704,12 +704,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -708,33 +708,42 @@
#define RETRACT_RECOVER_FEEDRATE 8 //default feedrate for recovering from retraction (mm/s) #define RETRACT_RECOVER_FEEDRATE 8 //default feedrate for recovering from retraction (mm/s)
#endif #endif
// Add support for experimental filament exchange support M600; requires display /**
#if ENABLED(ULTIPANEL) * Filament Change
#define FILAMENT_CHANGE_FEATURE // Enable filament exchange menu and M600 g-code (used for runout sensor too) * Experimental filament change support.
#if ENABLED(FILAMENT_CHANGE_FEATURE) * Adds the GCode M600 for initiating filament change.
#define FILAMENT_CHANGE_X_POS (X_MAX_POS-3) // X position of hotend *
#define FILAMENT_CHANGE_Y_POS 3 // Y position of hotend * Requires an LCD display.
#define FILAMENT_CHANGE_Z_ADD 10 // Z addition of hotend (lift) * This feature is required for the default FILAMENT_RUNOUT_SCRIPT.
#define FILAMENT_CHANGE_XY_FEEDRATE 100 // X and Y axes feedrate in mm/s (also used for delta printers Z axis) */
#define FILAMENT_CHANGE_Z_FEEDRATE 5 // Z axis feedrate in mm/s (not used for delta printers) //#define FILAMENT_CHANGE_FEATURE
#define FILAMENT_CHANGE_RETRACT_LENGTH 2 // Initial retract in mm #if ENABLED(FILAMENT_CHANGE_FEATURE)
// It is a short retract used immediately after print interrupt before move to filament exchange position #define FILAMENT_CHANGE_X_POS (X_MAX_POS-3) // X position of hotend
#define FILAMENT_CHANGE_RETRACT_FEEDRATE 60 // Initial retract feedrate in mm/s #define FILAMENT_CHANGE_Y_POS 3 // Y position of hotend
#define FILAMENT_CHANGE_UNLOAD_LENGTH 100 // Unload filament length from hotend in mm #define FILAMENT_CHANGE_Z_ADD 10 // Z addition of hotend (lift)
// Longer length for bowden printers to unload filament from whole bowden tube, #define FILAMENT_CHANGE_XY_FEEDRATE 100 // X and Y axes feedrate in mm/s (also used for delta printers Z axis)
// shorter lenght for printers without bowden to unload filament from extruder only, #define FILAMENT_CHANGE_Z_FEEDRATE 5 // Z axis feedrate in mm/s (not used for delta printers)
// 0 to disable unloading for manual unloading #define FILAMENT_CHANGE_RETRACT_LENGTH 2 // Initial retract in mm
#define FILAMENT_CHANGE_UNLOAD_FEEDRATE 10 // Unload filament feedrate in mm/s - filament unloading can be fast // It is a short retract used immediately after print interrupt before move to filament exchange position
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_RETRACT_FEEDRATE 60 // Initial retract feedrate in mm/s
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, #define FILAMENT_CHANGE_UNLOAD_LENGTH 100 // Unload filament length from hotend in mm
// Short or zero length for printers without bowden where loading is not used // Longer length for bowden printers to unload filament from whole bowden tube,
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast // shorter lenght for printers without bowden to unload filament from extruder only,
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, // 0 to disable unloading for manual unloading
// 0 to disable for manual extrusion #define FILAMENT_CHANGE_UNLOAD_FEEDRATE 10 // Unload filament feedrate in mm/s - filament unloading can be fast
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// or until outcoming filament color is not clear for filament color change // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate // Short or zero length for printers without bowden where loading is not used
#endif #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -695,33 +695,42 @@
#define RETRACT_RECOVER_FEEDRATE 8 //default feedrate for recovering from retraction (mm/s) #define RETRACT_RECOVER_FEEDRATE 8 //default feedrate for recovering from retraction (mm/s)
#endif #endif
// Add support for experimental filament exchange support M600; requires display /**
#if ENABLED(ULTIPANEL) * Filament Change
#define FILAMENT_CHANGE_FEATURE // Enable filament exchange menu and M600 g-code (used for runout sensor too) * Experimental filament change support.
#if ENABLED(FILAMENT_CHANGE_FEATURE) * Adds the GCode M600 for initiating filament change.
#define FILAMENT_CHANGE_X_POS 100 // X position of hotend *
#define FILAMENT_CHANGE_Y_POS 100 // Y position of hotend * Requires an LCD display.
#define FILAMENT_CHANGE_Z_ADD 20 // Z addition of hotend (lift) * This feature is required for the default FILAMENT_RUNOUT_SCRIPT.
#define FILAMENT_CHANGE_XY_FEEDRATE 100 // X and Y axes feedrate in mm/s (also used for delta printers Z axis) */
#define FILAMENT_CHANGE_Z_FEEDRATE 5 // Z axis feedrate in mm/s (not used for delta printers) //#define FILAMENT_CHANGE_FEATURE
#define FILAMENT_CHANGE_RETRACT_LENGTH 5 // Initial retract in mm #if ENABLED(FILAMENT_CHANGE_FEATURE)
// It is a short retract used immediately after print interrupt before move to filament exchange position #define FILAMENT_CHANGE_X_POS 100 // X position of hotend
#define FILAMENT_CHANGE_RETRACT_FEEDRATE 60 // Initial retract feedrate in mm/s #define FILAMENT_CHANGE_Y_POS 100 // Y position of hotend
#define FILAMENT_CHANGE_UNLOAD_LENGTH 600 // Unload filament length from hotend in mm #define FILAMENT_CHANGE_Z_ADD 20 // Z addition of hotend (lift)
// Longer length for bowden printers to unload filament from whole bowden tube, #define FILAMENT_CHANGE_XY_FEEDRATE 100 // X and Y axes feedrate in mm/s (also used for delta printers Z axis)
// shorter lenght for printers without bowden to unload filament from extruder only, #define FILAMENT_CHANGE_Z_FEEDRATE 5 // Z axis feedrate in mm/s (not used for delta printers)
// 0 to disable unloading for manual unloading #define FILAMENT_CHANGE_RETRACT_LENGTH 5 // Initial retract in mm
#define FILAMENT_CHANGE_UNLOAD_FEEDRATE 10 // Unload filament feedrate in mm/s - filament unloading can be fast // It is a short retract used immediately after print interrupt before move to filament exchange position
#define FILAMENT_CHANGE_LOAD_LENGTH 600 // Load filament length over hotend in mm #define FILAMENT_CHANGE_RETRACT_FEEDRATE 60 // Initial retract feedrate in mm/s
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, #define FILAMENT_CHANGE_UNLOAD_LENGTH 600 // Unload filament length from hotend in mm
// Short or zero length for printers without bowden where loading is not used // Longer length for bowden printers to unload filament from whole bowden tube,
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast // shorter lenght for printers without bowden to unload filament from extruder only,
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 100 // Extrude filament length in mm after filament is load over the hotend, // 0 to disable unloading for manual unloading
// 0 to disable for manual extrusion #define FILAMENT_CHANGE_UNLOAD_FEEDRATE 10 // Unload filament feedrate in mm/s - filament unloading can be fast
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// or until outcoming filament color is not clear for filament color change // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate // Short or zero length for printers without bowden where loading is not used
#endif #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 100 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -721,12 +721,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -721,12 +721,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -703,33 +703,42 @@
#define RETRACT_RECOVER_FEEDRATE 8 //default feedrate for recovering from retraction (mm/s) #define RETRACT_RECOVER_FEEDRATE 8 //default feedrate for recovering from retraction (mm/s)
#endif #endif
// Add support for experimental filament exchange support M600; requires display /**
#if ENABLED(ULTIPANEL) * Filament Change
#define FILAMENT_CHANGE_FEATURE // Enable filament exchange menu and M600 g-code (used for runout sensor too) * Experimental filament change support.
#if ENABLED(FILAMENT_CHANGE_FEATURE) * Adds the GCode M600 for initiating filament change.
#define FILAMENT_CHANGE_X_POS 3 // X position of hotend *
#define FILAMENT_CHANGE_Y_POS 3 // Y position of hotend * Requires an LCD display.
#define FILAMENT_CHANGE_Z_ADD 10 // Z addition of hotend (lift) * This feature is required for the default FILAMENT_RUNOUT_SCRIPT.
#define FILAMENT_CHANGE_XY_FEEDRATE 100 // X and Y axes feedrate in mm/s (also used for delta printers Z axis) */
#define FILAMENT_CHANGE_Z_FEEDRATE 5 // Z axis feedrate in mm/s (not used for delta printers) //#define FILAMENT_CHANGE_FEATURE
#define FILAMENT_CHANGE_RETRACT_LENGTH 2 // Initial retract in mm #if ENABLED(FILAMENT_CHANGE_FEATURE)
// It is a short retract used immediately after print interrupt before move to filament exchange position #define FILAMENT_CHANGE_X_POS 3 // X position of hotend
#define FILAMENT_CHANGE_RETRACT_FEEDRATE 60 // Initial retract feedrate in mm/s #define FILAMENT_CHANGE_Y_POS 3 // Y position of hotend
#define FILAMENT_CHANGE_UNLOAD_LENGTH 100 // Unload filament length from hotend in mm #define FILAMENT_CHANGE_Z_ADD 10 // Z addition of hotend (lift)
// Longer length for bowden printers to unload filament from whole bowden tube, #define FILAMENT_CHANGE_XY_FEEDRATE 100 // X and Y axes feedrate in mm/s (also used for delta printers Z axis)
// shorter lenght for printers without bowden to unload filament from extruder only, #define FILAMENT_CHANGE_Z_FEEDRATE 5 // Z axis feedrate in mm/s (not used for delta printers)
// 0 to disable unloading for manual unloading #define FILAMENT_CHANGE_RETRACT_LENGTH 2 // Initial retract in mm
#define FILAMENT_CHANGE_UNLOAD_FEEDRATE 10 // Unload filament feedrate in mm/s - filament unloading can be fast // It is a short retract used immediately after print interrupt before move to filament exchange position
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_RETRACT_FEEDRATE 60 // Initial retract feedrate in mm/s
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, #define FILAMENT_CHANGE_UNLOAD_LENGTH 100 // Unload filament length from hotend in mm
// Short or zero length for printers without bowden where loading is not used // Longer length for bowden printers to unload filament from whole bowden tube,
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast // shorter lenght for printers without bowden to unload filament from extruder only,
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, // 0 to disable unloading for manual unloading
// 0 to disable for manual extrusion #define FILAMENT_CHANGE_UNLOAD_FEEDRATE 10 // Unload filament feedrate in mm/s - filament unloading can be fast
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// or until outcoming filament color is not clear for filament color change // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate // Short or zero length for printers without bowden where loading is not used
#endif #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -721,12 +721,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -723,12 +723,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -723,12 +723,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -728,12 +728,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -723,12 +723,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -721,12 +721,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

@ -721,12 +721,16 @@
#define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm #define FILAMENT_CHANGE_LOAD_LENGTH 0 // Load filament length over hotend in mm
// Longer length for bowden printers to fast load filament into whole bowden tube over the hotend, // Longer length for bowden printers to fast load filament into whole bowden tube over the hotend,
// Short or zero length for printers without bowden where loading is not used // Short or zero length for printers without bowden where loading is not used
#define FILAMENT_CHANGE_LOAD_FEEDRATE 10 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast #define FILAMENT_CHANGE_LOAD_FEEDRATE 6 // Load filament feedrate in mm/s - filament loading into the bowden tube can be fast
#define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend, #define FILAMENT_CHANGE_EXTRUDE_LENGTH 50 // Extrude filament length in mm after filament is load over the hotend,
// 0 to disable for manual extrusion // 0 to disable for manual extrusion
// Filament can be extruded repeatedly from the filament exchange menu to fill the hotend, // Filament can be extruded repeatedly from the filament exchange menu to fill the hotend,
// or until outcoming filament color is not clear for filament color change // or until outcoming filament color is not clear for filament color change
#define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate #define FILAMENT_CHANGE_EXTRUDE_FEEDRATE 3 // Extrude filament feedrate in mm/s - must be slower than load feedrate
#define FILAMENT_CHANGE_NOZZLE_TIMEOUT 45L // Turn off nozzle if user doesn't change filament within this time limit in seconds
#define FILAMENT_CHANGE_NUMBER_OF_ALERT_BEEPS 5L // Number of alert beeps before printer goes quiet
#define FILAMENT_CHANGE_NO_STEPPER_TIMEOUT // Enable to have stepper motors hold position during filament change
// even if it takes longer than DEFAULT_STEPPER_DEACTIVE_TIME.
#endif #endif
/******************************************************************************\ /******************************************************************************\

Loading…
Cancel
Save