Add XY parameters to G29 for mesh dimensions

2.0.x
Scott Lahteine 8 years ago
parent 56cf674150
commit 81b8c9f8ec

@ -3635,24 +3635,31 @@ inline void gcode_G28() {
#if ABL_GRID #if ABL_GRID
#if ABL_PLANAR
bool do_topography_map = verbose_level > 2 || code_seen('T');
#endif
if (verbose_level > 0) { if (verbose_level > 0) {
SERIAL_PROTOCOLLNPGM("G29 Auto Bed Leveling"); SERIAL_PROTOCOLLNPGM("G29 Auto Bed Leveling");
if (dryrun) SERIAL_PROTOCOLLNPGM("Running in DRY-RUN mode"); if (dryrun) SERIAL_PROTOCOLLNPGM("Running in DRY-RUN mode");
} }
int abl_grid_points_x = ABL_GRID_POINTS_X,
abl_grid_points_y = ABL_GRID_POINTS_Y;
#if ABL_PLANAR #if ABL_PLANAR
bool do_topography_map = verbose_level > 2 || code_seen('T');
// X and Y specify points in each direction, overriding the default
// These values may be saved with the completed mesh
int abl_grid_points_x = code_seen('X') ? code_value_int() : ABL_GRID_POINTS_X,
abl_grid_points_y = code_seen('Y') ? code_value_int() : ABL_GRID_POINTS_Y;
if (code_seen('P')) abl_grid_points_x = abl_grid_points_y = code_value_int(); if (code_seen('P')) abl_grid_points_x = abl_grid_points_y = code_value_int();
if (abl_grid_points_x < 2) {
SERIAL_PROTOCOLLNPGM("?Number of probed (P)oints is implausible (2 minimum)."); if (abl_grid_points_x < 2 || abl_grid_points_y < 2) {
SERIAL_PROTOCOLLNPGM("?Number of probe points is implausible (2 minimum).");
return; return;
} }
#else
const int abl_grid_points_x = ABL_GRID_POINTS_X, abl_grid_points_y = ABL_GRID_POINTS_Y;
#endif #endif
xy_probe_feedrate_mm_s = MMM_TO_MMS(code_seen('S') ? code_value_linear_units() : XY_PROBE_SPEED); xy_probe_feedrate_mm_s = MMM_TO_MMS(code_seen('S') ? code_value_linear_units() : XY_PROBE_SPEED);

Loading…
Cancel
Save