Disable PROBE_MANUALLY for UBL

Plus some other UBL tweaks.
2.0.x
Scott Lahteine 8 years ago
parent 94a4af1d7f
commit 75badae2f8

@ -373,6 +373,13 @@
*/
#define HAS_Z_SERVO_ENDSTOP (defined(Z_ENDSTOP_SERVO_NR) && Z_ENDSTOP_SERVO_NR >= 0)
/**
* UBL has its own manual probing, so this just causes trouble.
*/
#if ENABLED(AUTO_BED_LEVELING_UBL)
#undef PROBE_MANUALLY
#endif
/**
* Set a flag for any enabled probe
*/

@ -351,6 +351,9 @@ int16_t code_value_temp_diff();
void refresh_zprobe_zoffset(const bool no_babystep=false);
#define DEPLOY_PROBE() set_probe_deployed(true)
#define STOW_PROBE() set_probe_deployed(false)
#else
#define DEPLOY_PROBE()
#define STOW_PROBE()
#endif
#if ENABLED(HOST_KEEPALIVE_FEATURE)

@ -463,16 +463,16 @@ static_assert(1 >= 0
#if ENABLED(BLTOUCH)
+ 1
#endif
#if ENABLED(Z_PROBE_ALLEN_KEY)
#if ENABLED(SOLENOID_PROBE)
+ 1
#endif
#if ENABLED(Z_PROBE_SLED)
#if ENABLED(Z_PROBE_ALLEN_KEY)
+ 1
#endif
#if ENABLED(SOLENOID_PROBE)
#if ENABLED(Z_PROBE_SLED)
+ 1
#endif
, "Please enable only one probe: PROBE_MANUALLY, FIX_MOUNTED_PROBE, Z Servo, BLTOUCH, Z_PROBE_ALLEN_KEY, or Z_PROBE_SLED."
, "Please enable only one probe option: PROBE_MANUALLY, FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or Z Servo."
);
@ -547,9 +547,13 @@ static_assert(1 >= 0
* Require some kind of probe for bed leveling and probe testing
*/
#if HAS_ABL
#error "Auto Bed Leveling requires a probe! Define a Z Servo, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or FIX_MOUNTED_PROBE."
#if ENABLED(AUTO_BED_LEVELING_UBL)
#error "Unified Bed Leveling requires a probe: FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or Z Servo."
#else
#error "Auto Bed Leveling requires one of these: PROBE_MANUALLY, FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or a Z Servo."
#endif
#elif ENABLED(Z_MIN_PROBE_REPEATABILITY_TEST)
#error "Z_MIN_PROBE_REPEATABILITY_TEST requires a probe! Define a Z Servo, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or FIX_MOUNTED_PROBE."
#error "Z_MIN_PROBE_REPEATABILITY_TEST requires a probe: FIX_MOUNTED_PROBE, BLTOUCH, SOLENOID_PROBE, Z_PROBE_ALLEN_KEY, Z_PROBE_SLED, or Z Servo."
#endif
#endif

@ -640,10 +640,10 @@
ubl.state.z_offset = code_value_float(); // do the simple case. Just lock in the specified value
else {
ubl.save_ubl_active_state_and_disable();
//measured_z = probe_pt(x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER, ProbeDeployAndStow, g29_verbose_level);
//float measured_z = probe_pt(x_pos + X_PROBE_OFFSET_FROM_EXTRUDER, y_pos + Y_PROBE_OFFSET_FROM_EXTRUDER, ProbeDeployAndStow, g29_verbose_level);
ubl.has_control_of_lcd_panel = true; // Grab the LCD Hardware
measured_z = 1.5;
float measured_z = 1.5;
do_blocking_move_to_z(measured_z); // Get close to the bed, but leave some space so we don't damage anything
// The user is not going to be locking in a new Z-Offset very often so
// it won't be that painful to spin the Encoder Wheel for 1.5mm
@ -1185,9 +1185,12 @@
SERIAL_PROTOCOL_F(planner.z_fade_height, 4);
SERIAL_EOL;
#endif
#if HAS_BED_PROBE
SERIAL_PROTOCOLPGM("zprobe_zoffset: ");
SERIAL_PROTOCOL_F(zprobe_zoffset, 7);
SERIAL_EOL;
#endif
SERIAL_ECHOLNPAIR("UBL_MESH_MIN_X " STRINGIFY(UBL_MESH_MIN_X) "=", UBL_MESH_MIN_X);
SERIAL_ECHOLNPAIR("UBL_MESH_MIN_Y " STRINGIFY(UBL_MESH_MIN_Y) "=", UBL_MESH_MIN_Y);

Loading…
Cancel
Save