Merge pull request #96 from haxar/Marlin_v1

make analog2tempBed return a precise celsius reading for BED_USES_THERMISTOR, ...
2.0.x
ErikZalm 13 years ago
commit 2422a857a1

@ -397,7 +397,7 @@ float analog2temp(int raw, uint8_t e) {
// For bed temperature measurement.
float analog2tempBed(int raw) {
#ifdef BED_USES_THERMISTOR
int celsius = 0;
float celsius = 0;
byte i;
raw = (1023 * OVERSAMPLENR) - raw;
@ -408,9 +408,8 @@ float analog2tempBed(int raw) {
{
celsius = PGM_RD_W(bedtemptable[i-1][1]) +
(raw - PGM_RD_W(bedtemptable[i-1][0])) *
(PGM_RD_W(bedtemptable[i][1]) - PGM_RD_W(bedtemptable[i-1][1])) /
(PGM_RD_W(bedtemptable[i][0]) - PGM_RD_W(bedtemptable[i-1][0]));
(float)(PGM_RD_W(bedtemptable[i][1]) - PGM_RD_W(bedtemptable[i-1][1])) /
(float)(PGM_RD_W(bedtemptable[i][0]) - PGM_RD_W(bedtemptable[i-1][0]));
break;
}
}
@ -419,13 +418,12 @@ float analog2tempBed(int raw) {
if (i == bedtemptable_len) celsius = PGM_RD_W(bedtemptable[i-1][1]);
return celsius;
#elif defined BED_USES_AD595
return ((raw * ((5.0 * 100.0) / 1024.0) / OVERSAMPLENR) * TEMP_SENSOR_AD595_GAIN) + TEMP_SENSOR_AD595_OFFSET;
#else
#warning No heater-type defined for the bed.
#endif
return 0;
#endif
}
void tp_init()

Loading…
Cancel
Save