Replaced stock BQ PID values with fine tuned ones generated using M303

2.0.x
jbrazio 9 years ago committed by Scott Lahteine
parent 45dc8a51f3
commit 02b131b552

@ -208,21 +208,15 @@ Here are some standard links for getting your machine calibrated:
#define PID_INTEGRAL_DRIVE_MAX PID_MAX //limit for the integral term
#define K1 0.95 //smoothing factor within the PID
// If you are using a pre-configured hotend then you can use one of the value sets by uncommenting it
// Ultimaker
#define DEFAULT_Kp 10.7
#define DEFAULT_Ki 0.45
#define DEFAULT_Kd 3
// MakerGear
//#define DEFAULT_Kp 7.0
//#define DEFAULT_Ki 0.1
//#define DEFAULT_Kd 12
// Mendel Parts V9 on 12V
//#define DEFAULT_Kp 63.0
//#define DEFAULT_Ki 2.25
//#define DEFAULT_Kd 440
// Tuned PID values using M303
#define DEFAULT_Kp 18.92
#define DEFAULT_Ki 1.37
#define DEFAULT_Kd 65.57
// BQ firmware stock PID values
//#define DEFAULT_Kp 10.7
//#define DEFAULT_Ki 0.45
//#define DEFAULT_Kd 3
#endif // PIDTEMP

Loading…
Cancel
Save