Scott Lahteine
d7c6fd5c2f
Merge pull request #3146 from thinkyhead/rc_enabled_true_false
...
Support "true" and "false" in the ENABLED macro
9 years ago
Scott Lahteine
6e1bc03d3b
Additional wrapping for #3140
9 years ago
Scott Lahteine
1c384930f3
Merge pull request #3140 from thinkyhead/rc_fix_macro_expansion
...
Wrap macros to prevent bad expansions
9 years ago
esenapaj
a4314c4907
Use local variable in recalc_delta_settings()
...
diagonal_rod hadn't been used anywhere.
9 years ago
Scott Lahteine
4b648793f2
Use ENABLED with DISABLE_[INACTIVE_][XYZ]
9 years ago
Scott Lahteine
3f5fbbd398
Merge pull request #3124 from jbrazio/bugfix/update-g29-auto-level-bed-topography
...
Update the bed topography output done by G29
9 years ago
Scott Lahteine
f9ded2a7c4
Wrap macros to prevent bad expansions
9 years ago
jbrazio
1981e53d68
M109 R option if misused could cause a wait-forever situation
9 years ago
João Brázio
4d4a842cfb
Update the bed topography output done by G29
9 years ago
AnHardt
fd5414c6ea
Z_RAISE_BEFORE_HOMING -> MIN_Z_HEIGHT_FOR_HOMING
...
rebased
corrected spelling
changed to #elif for error
Still with MIN_Z_HEIGHT_FOR_HOMING but con be done with (folder wide) search-replace when we have a better name.
9 years ago
Scott Lahteine
b7928a000a
Merge pull request #3108 from AnHardt/M110+
...
M110 and M29 rework
9 years ago
Scott Lahteine
5cba0b4187
Merge pull request #3111 from thinkyhead/rc_drop_old_condition
...
Drop obsolete test for leading "N"
9 years ago
Scott Lahteine
302d1bfbc4
Drop obsolete test for leading "N"
9 years ago
AnHardt
37b857e8ec
M110 ang M29 rework
...
Add 'ok' output for G29 actually closing the file.
Handle M110 when received without linenumber/checksumm.
9 years ago
Scott Lahteine
fac85f6fa1
Merge pull request #3102 from jbrazio/bugfix-g28-multiple-z-movements
...
Bugfix: G28 was lifting Z-axis multiple times
9 years ago
jbrazio
642e3699ce
Z-axis was being lift multiple times if Z_SAFE_HOMING was enabled and Z_RAISE_BEFORE_HOMING was greater than zero
9 years ago
Scott Lahteine
501f63802a
Merge pull request #3077 from Blue-Marlin/watchdogreset-in-kill
...
Add Watchdog timer reset in kill()
9 years ago
Scott Lahteine
ef68c1910c
Check that the temperature is close to target
9 years ago
Scott Lahteine
ea9fd1200b
Fix M109 so it won't wait for cooling
...
Addressing issue #2767
9 years ago
Scott Lahteine
ff13070b59
Use _BV macros, patch up others
9 years ago
Scott Lahteine
209f5f21e0
Use macros where possible
...
Apply `constrain`, `NOMORE`, `NOLESS` and `CRITICAL_SECTION` macros
wherever possible.
9 years ago
Scott Lahteine
6e64895c30
Merge pull request #3001 from AlwaysTinkering/RCBugFix
...
Rc bug fix - Fix for issue #2931
9 years ago
Scott Lahteine
34b8b9f0f5
Merge pull request #2995 from thinkyhead/rcbugfix_corexy_corexz
...
Add CORE support to st_get_position_mm (and elsewhere)
9 years ago
Scott Lahteine
3a3d358df9
Fix Printrboard with LCD (redo)
...
Based on #2860 - rebased for RCBugFix
9 years ago
Scott Lahteine
eb85342fd9
Merge pull request #2989 from AnHardt/fix2661
...
Pre home display - Stepper release
9 years ago
Scott Lahteine
14f3ca1b2e
Merge pull request #2978 from thinkyhead/tool_offset_abl_rcbugfix
...
Apply bed leveling matrix when switching extruders
9 years ago
lrpirlet
0fb507a75d
correct raise_z_for_servo
9 years ago
Blue-Marlin
b4e5e0f11d
Add Watchdog reset in kill()
...
Add watchdog reset in the kill loop to simplify recovering.
9 years ago
Scott Lahteine
222d13d5ed
Merge pull request #3051 from thinkyhead/rcbugfix_dual_axis_offset
...
Code cleanup in gcode_T
9 years ago
Scott Lahteine
186629aee8
Merge pull request #3057 from jbrazio/3034-z_raise_after_probing_fix
...
Fix Z_RAISE_AFTER_PROBING for non DELTA printers
9 years ago
jbrazio
67e15aac3d
As pointed out by @Blue-Marlin the previous code would raise the Z axis
...
twice for a servo based probe.
9 years ago
jbrazio
17cc2a9663
Z_RAISE_AFTER_PROBING value was being ignored by Marlin because
...
raise_z_after_probing() was only called if the printer type was set to a
DELTA or if the printer had a docking sled for the probe.
9 years ago
AnHardt
1c889cd303
Refresh previous_cmd_ms during run_z_probe()
...
Refresh previous_cmd_ms during run_z_probe() to prevent:
stepper shutdown for expired DEFAULT_STEPPER_DEACTIVE_TIME
and extrudes for expired EXTRUDER_RUNOUT_SECONDS
(https://github.com/MarlinFirmware/MarlinDev/issues/238 )
9 years ago
AnHardt
4b02f33e69
Distribute config-changes to the other configurations
9 years ago
AnHardt
32ae9f9ab7
Fix stepper shutdown during waiting for temperatures
...
In the wait loops of M109 M190 idle() is called, what checks
stepper_inactive_time against previous_cmd_ms.
Because we can be several minutes inside the loop, resetting
previous_cmd_ms only outside the loop caused stepper shutdowns.
The name of previous_cmd_ms does not really reflect its use. It's set
not only when a new command was received or executed but also in many of
the movement routines. For that the little extension of using it during
the wait will (hopefully) not hurt.
# Conflicts:
# Marlin/Configuration_adv.h
9 years ago
AnHardt
b6e69e71ce
Make stepper shutdown after inactivity dependent
...
Make stepper shutdown after inactivity dependent on a new set of
#defines.
DISABLE_INACTIV_X
DISABLE_INACTIV_Y
DISABLE_INACTIV_Z
DISABLE_INACTIV_E
And make exemplaric Configuration.
Names can be discussed.
This makes the disabling of the steppers independent from the DISABLE_?
settings witch shut down the steppers immediately.
9 years ago
AnHardt
051325ccd7
Introduce axis_homed
...
Introduce additional variable axis_homed to replace axix_known_position
when the coordinate display should indicate the axis is not homed.
This is to distinguish between "not homed" and "inexact position possible
because stepper was disabled".
# Conflicts:
# Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
9 years ago
Scott Lahteine
100271e6ac
minor cleanup in gcode_T
9 years ago
Scott Lahteine
6a4f06d35d
Fix GCode handling of spaces between command letter and first digit
9 years ago
CONSULitAS
ea8409ad5d
Fix: current_command_args contains command
...
@thinkyhead
Hi Scott,
your code from a0f362c@thinkyhead is great, but you forgot to skip the
command.
Symptom `M117 Test`shows `M117 Test` on LCD instead of `Test`.
see also
https://github.com/MarlinFirmware/Marlin/commit/a0f362c735401ebbcd95de3f
6f8e3c2f17ecc770 lines 941, 2851 and so on
Greetings and welcome back
Jochen
9 years ago
Scott Lahteine
e1beaf61eb
Merge pull request #2985 from AnHardt/adv-ok
...
Repair N in ADVANCED_OK
9 years ago
Scott Lahteine
0c9db67273
Merge pull request #2983 from AnHardt/ok-echo
...
Replace the "ok" in M280, M301, M304, M851 with output not including …
9 years ago
Scott Lahteine
8eaba020fb
Merge pull request #2973 from thinkyhead/fix_splash_url
...
Remove references to marlinfirmware.org
9 years ago
Scott Lahteine
be691b51f1
Remove references to marlinfirmware.org
...
The domain is gone and doesn’t redirect, so for now show no URL on the boot screen.
9 years ago
Scott Lahteine
83ffc9eb4f
Show raw steps in M114
...
This is a proposed change. This section of M114 output is a debug
extension according to RepRap wiki.
9 years ago
Scott Lahteine
373e8a1ad4
Fixes for COREXY and COREXZ coordinates
9 years ago
unknown
31656e68bc
Fix for homing X and Y before raising Z when Z_SAFE_HOMING is set.
9 years ago
unknown
8ea55323d8
Fix for not raising Z before homing X and Y
9 years ago
Scott Lahteine
711e5db19a
Tweak comment in process_next_command
9 years ago
Scott Lahteine
400e9329be
Allow spaces after a code letter
9 years ago