3996 Commits (e4945b30d27dd5c748085d1fad457350dc692a44)
 

Author SHA1 Message Date
Scott Lahteine e4945b30d2 sbi and cbi are deprecated 9 years ago
Scott Lahteine ff13070b59 Use _BV macros, patch up others 9 years ago
Scott Lahteine 209f5f21e0 Use macros where possible
Apply `constrain`, `NOMORE`, `NOLESS` and `CRITICAL_SECTION` macros
wherever possible.
9 years ago
Scott Lahteine c8f76bb8aa Create BITSET/BITCLR macros 9 years ago
Scott Lahteine adc25db8c4 Merge pull request #3005 from thinkyhead/rcbugfix_eeprom
Fix layout descr. in configuration_store.cpp
9 years ago
Scott Lahteine e7cf85b922 Merge pull request #3013 from thinkyhead/esenapaj-patch-1
Enhanced #3010 - formal Mesh/Manual dependency
9 years ago
Scott Lahteine 6e64895c30 Merge pull request #3001 from AlwaysTinkering/RCBugFix
Rc bug fix - Fix for issue #2931
9 years ago
Scott Lahteine 34b8b9f0f5 Merge pull request #2995 from thinkyhead/rcbugfix_corexy_corexz
Add CORE support to st_get_position_mm (and elsewhere)
9 years ago
Scott Lahteine 1e20949afb Merge pull request #3092 from thinkyhead/rc_2860_printrbot_lcd
Fix Printrboard with LCD (redo)
9 years ago
Scott Lahteine f5972c4d2c Merge pull request #2994 from AnHardt/Inerrup-save-serial
Interrupt safe serial --- Guard against non-atomic variable changes from interrupt routines
9 years ago
Scott Lahteine 3a3d358df9 Fix Printrboard with LCD (redo)
Based on #2860 - rebased for RCBugFix
9 years ago
Scott Lahteine eb85342fd9 Merge pull request #2989 from AnHardt/fix2661
Pre home display - Stepper release
9 years ago
Scott Lahteine 14f3ca1b2e Merge pull request #2978 from thinkyhead/tool_offset_abl_rcbugfix
Apply bed leveling matrix when switching extruders
9 years ago
Scott Lahteine 91fcdc2b99 Merge pull request #3090 from thinkyhead/rc_spelling
Various minor spelling corrections
9 years ago
Scott Lahteine 772460a7b8 Various minor spelling corrections
Redo of #2939 rebased against RCBugFix
9 years ago
Scott Lahteine aa0b0483f4 Merge pull request #3089 from thinkyhead/rc_apply_2924
Correct raise_z_for_servo for Z offsets below the nozzle
9 years ago
lrpirlet 0fb507a75d correct raise_z_for_servo 9 years ago
Scott Lahteine 04a0d45c22 Merge pull request #2821 from MarlinFirmware/ReinitializeDisplay
Fix status LEDs update when reinitializing the display
9 years ago
Scott Lahteine 547d35a921 Merge pull request #3067 from Blue-Marlin/ALARM_PIN
Remove unused ALARM_PIN
9 years ago
Scott Lahteine 79778d46d9 Merge pull request #3066 from Blue-Marlin/Fix-disable_all_heaters()
Fix disable_all_heaters() for MAX6675
9 years ago
Blue-Marlin a68228bf55 Remove unused ALARM_PIN
Remove unused ALARM_PIN from all the Configuration.h's
9 years ago
Scott Lahteine 9eb4aceee4 Merge pull request #2986 from thinkyhead/enable_watchdog
Enable USE_WATCHDOG by default
9 years ago
Blue-Marlin 0631541166 Fix disable_all_heaters() for MAX6675 9 years ago
Scott Lahteine 222d13d5ed Merge pull request #3051 from thinkyhead/rcbugfix_dual_axis_offset
Code cleanup in gcode_T
9 years ago
Scott Lahteine 186629aee8 Merge pull request #3057 from jbrazio/3034-z_raise_after_probing_fix
Fix Z_RAISE_AFTER_PROBING for non DELTA printers
9 years ago
Scott Lahteine a42fb35c56 Merge pull request #3050 from Blue-Marlin/fix-1166
Temporary workaround for stack overflow
9 years ago
jbrazio 67e15aac3d As pointed out by @Blue-Marlin the previous code would raise the Z axis
twice for a servo based probe.
9 years ago
jbrazio 17cc2a9663 Z_RAISE_AFTER_PROBING value was being ignored by Marlin because
raise_z_after_probing() was only called if the printer type was set to a
DELTA or if the printer had a docking sled for the probe.
9 years ago
Scott Lahteine 252f4a75cd Merge pull request #3043 from oxivanisher/RCBugFix
Example configuration for Kossel XL
9 years ago
Scott Lahteine fd1243c184 Merge pull request #3052 from thinkyhead/rc_fix_m145_eeprom_output
Fix "M145" output in M503 report
9 years ago
Scott Lahteine 0bc648353f Merge pull request #3031 from tnw513/RCBugFix
Fix board type for Hephestos: RAMPS 1.4
9 years ago
AnHardt f27c2b6b4b Reimplement #2892
Include #2892 to fix the isHeating symbol in the extruder graphics
9 years ago
AnHardt 615bec2329 Activate warning about possible reduced accuracy by default
Renamed `WARN_REDUCED_ACCURACY` to `DISABLE_REDUCED_ACCURACY_WARNING`

Changed the condition for blinking from
```
#if ENABLED(WARN_REDUCED_ACCURACY)
```
to
```
#if DISABLED(DISABLE_REDUCED_ACCURACY_WARNING)
```
9 years ago
AnHardt 1c889cd303 Refresh previous_cmd_ms during run_z_probe()
Refresh previous_cmd_ms during run_z_probe() to prevent:
stepper shutdown for expired DEFAULT_STEPPER_DEACTIVE_TIME
and extrudes for expired EXTRUDER_RUNOUT_SECONDS
(https://github.com/MarlinFirmware/MarlinDev/issues/238)
9 years ago
AnHardt 4b02f33e69 Distribute config-changes to the other configurations 9 years ago
AnHardt be24fdacea The same changes to the axis-letters now for the char-displays
Exactly the same - copy/paste.
9 years ago
AnHardt 5b0f659355 Changes for graphics displays
Replaced displaying "---" instead of the value of a coordinate when
unhomed or with reduced precision
with blinking the coordinate-prefix-character ('X','Y','Z').
For "unhomed" a '?' is shown every second second - until that axis is
homed. The value displayed is, as before the "---" where displayed, the
relative to the reset position coordinate value.
When the axis stepper was disabled, now we can display a hint on that,
by showing a blinking ' ' instead of the axis letter, when
WARN_REDUCED_ACCURACY is defined.

I suppose the code itself is here the better documentation.

A '+/-' character is in non of our charsets so i decided for a '?' for
now to reduce the work.
There is no additional space on the displays one could use to display
the information, so replacing something is the only option. As the axis
letters are totally redundant with their positions on the display they
contain the least information.
So my decision was to overwrite them.
9 years ago
AnHardt 32ae9f9ab7 Fix stepper shutdown during waiting for temperatures
In the wait loops of M109 M190 idle() is called, what checks
stepper_inactive_time against previous_cmd_ms.
Because we can be several minutes inside the loop, resetting
previous_cmd_ms only outside the loop caused stepper shutdowns.

The name of previous_cmd_ms does not really reflect its use. It's set
not only when a new command was received or executed but also in many of
the movement routines. For that the little extension of using it during
the wait will (hopefully) not hurt.

# Conflicts:
#	Marlin/Configuration_adv.h
9 years ago
AnHardt b6e69e71ce Make stepper shutdown after inactivity dependent
Make stepper shutdown after inactivity dependent on a new set of
#defines.
DISABLE_INACTIV_X
DISABLE_INACTIV_Y
DISABLE_INACTIV_Z
DISABLE_INACTIV_E

And make exemplaric Configuration.
Names can be discussed.

This makes the disabling of the steppers independent from the DISABLE_?
settings witch shut down the steppers immediately.
9 years ago
AnHardt 051325ccd7 Introduce axis_homed
Introduce additional variable axis_homed to replace axix_known_position
when the coordinate display should indicate the axis is not homed.
This is to distinguish between "not homed" and "inexact position possible
because stepper was disabled".

# Conflicts:
#	Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
9 years ago
AnHardt e736779d7e blink for char-lcds
Implement and test blinking for char-lcds

# Conflicts:
#	Marlin/ultralcd_implementation_hitachi_HD44780.h
solved
9 years ago
Scott Lahteine 7253a1971d Fix "M145" output in M503 report 9 years ago
Scott Lahteine d118e3f985 Merge pull request #3044 from thinkyhead/rc_gcode_spaces
Fix GCode handling of spaces between command letter and first digit
9 years ago
Scott Lahteine 100271e6ac minor cleanup in gcode_T 9 years ago
Blue-Marlin fd9e94e5a4 Fix crashes when the Z axis is moved via LCD
Fix crashes when the Z axis is moved via LCD
by calling `plan_buffer_line` only when there is enough room in the
planner buffer, to avoid endless recursion.
A brief description about what went wrong is in #1166
9 years ago
Scott Lahteine 8dccd5a7ea Merge pull request #3018 from CONSULitAS/RCBugFix_K8200_backinsync
K8200: sample config back in sync
9 years ago
Scott Lahteine 6a4f06d35d Fix GCode handling of spaces between command letter and first digit 9 years ago
Marc Urben 68eae2b5a8 added kossel xl example configuration 9 years ago
Silvio Didonna eb5817675d Fix board type: RAMPS 1.4 9 years ago
Scott Lahteine 8006684c19 Merge pull request #3027 from CONSULitAS/RCBugFix_current_command
Fix: current_command_args contains command
9 years ago