A `z_before` value is passed to probe_pt, but the `retract_z_probe`
function assumes that Z is 0, doesn’t add `current_position[Z_AXIS]` as
other cases do. This may be superfluous, so this is a test, and will be
reverted if it has no effect.
- Fix `prepare_move` function not calling `adjust_delta`
- Add more shorthand for plan_buffer_line.
- Fix wrong `federate` usage, assuming they are all mm/m
- Minor `stepper.cpp` cleanup
- Users prefer `G29 E` to work like `M48 E` so fixed that
- `M48 n` replaced with `M48 P` (or `p`). `n` legacy support
- Shorten some strings to save precious bytes
- Smaller code for 3-point probing
- Fixed a typo causing G28 to home incorrectly
- Added documentation to G28
- Added homeXYZ bools to neaten the code
- Added a note about home_offsets being questionable
- Add some documentation to planner and stepper headers
- Patch up RAMBO pins with undefs
- Add `sync_plan_position` inline to set current XYZE
- Swap indices in `extruder_offset` to fix initialization values
Z_DUAL_ENDSTOPS is a feature to enable the use of 2 endstops for both Z
steppers - Let's call them Z stepper and Z2 stepper.
That way the machine is capable to align the bed during home, since both
Z steppers are homed.
There is also an implementation of M666 (software endstops adjustment)
to this feature.
After Z homing, this adjustment is applied to just one of the steppers
in order to align the bed.
One just need to home the Z axis and measure the distance difference
between both Z axis and apply the math: Z adjust = Z - Z2.
If the Z stepper axis is closer to the bed, the measure Z > Z2 (yes, it
is.. think about it) and the Z adjust would be positive.
Play a little bit with small adjustments (0.5mm) and check the
behaviour.
The M119 (endstops report) will start reporting the Z2 Endstop as well.
- Add `Conditionals.h` with calculated configuration values
- Add `SanityCheck.h` with checks for configuration errors
- Remove equivalent code from all configurations
- Move error checks from some sources to `SanityCheck.h` also
- Fix initialization of count_direction in stepper.cpp
- Add BIT and TEST macros
- Add _APPLY_ macros to stepper.cpp to help with consolidation
- Consolidate code in stepper.cpp using macros
- Apply standards in stepper.cpp
- Use >= 0 instead of > -1 as a better semantic
- Replace DUAL_Y_CARRIAGE with Y_DUAL_STEPPER_DRIVERS
Added option to set Travel Acceleration (non printing moves).
The M204 options was a non sense (S for printing moves and T for retract
moves).
It has been changed to:
P = Printing moves
R = Retract only (no X, Y, Z) moves
T = Travel (non
printing) moves
I will add this info o G-Code wiki in reprap.org. I also advise to put
this info in Marlin next version changelog.
With this change a mechanical or optical switch may be used to check the
availability of the filament and when the filament runs out an M600
(filament change) command is issued. This is only done while printing
with an SD card.
This feature was requested several times (issue #679), but the requests
were not accepted since it was believed that this situation should be
handled at host side. However during an SD print the control is totally
on firmware and I think that during an SD print it should be handled by
the firmware.
The original code was posted at reprap forum
(http://forums.reprap.org/read.php?1,297350) by Lazymonk. I have only
corrected some bugs of the code and improved it by adding definitions to
the configuration.h in order to make it more standardized.
- Nonlinear auto bed leveling code (includes G29, G30, Z_RAISE_AFTER_PROBING). Cleaned it up to be a delta-specific AUTO_BED_LEVELING_GRID code path.
- Allen key z-probe deployment and retraction code. Cleaned it up and added safety checks.