1504 Commits (46843bd927c59c498ac8c229f31728795688b79e)

Author SHA1 Message Date
Steffen Vogel 69dc411ae0 Merge branch 'Development' of github.com:MarlinFirmware/Marlin into LogoLCD
Conflicts:
	Marlin/dogm_lcd_implementation.h
10 years ago
Scott Lahteine 326b925557 DOGLCD and LCD_PROGRESS_BAR to coexist
Small changes (and formatting to confuse the diff’er) which first
allows DOGLCD and LCD_PROGRESS_BAR to be enabled in tandem, then a
#warning (rather than error) that the extra progress bar / message
options don’t apply to graphical displays at this time. This leaves
open perhaps combining the progress bar and message area in some future
(or forked custom) graphical LCD display arrangement (at which time the
relevant variables may be moved into ultralcd.cpp with externs in
ultralcd.h). I also added a conditional error that the progress bar and
the filament display may not work well together.
10 years ago
Erik van der Zalm 1aade4a8e2 Merge branch 'Development' of https://github.com/MarlinFirmware/Marlin into Development 10 years ago
Erik van der Zalm 8a2e84e3f1 Possible fix for FWRETRACT with 0 zlift. 10 years ago
Steffen Vogel 905aab3b85 added missing #endif 10 years ago
Steffen Vogel b9cf1465a7 updated LCD bouts with new strings and bitmaps
new version is pretty generic and should work in most scenarios
10 years ago
Steffen Vogel c7632be5cc added high and low resolutions version of splash screen logo (saving code size) 10 years ago
Steffen Vogel 8f0dba7cbf adding string for bouts splash string to config 10 years ago
Bo Herrmannsen d94109e886 updated logo post and ver info 10 years ago
Bo Herrmannsen cd33b5b062 changed logo and ver info
logo is now 110 pixels wide and starts 9 pixels in from top left corner and also 9 pixels down from same corner... this will give a 9 pixel border all way round

ver info is placed centered and there is a 9 pixel from bottom of display to ver info
10 years ago
Bo Herrmannsen 9b6c1cfda6 removed unneeded lines in welcome msg 10 years ago
Bo Herrmannsen ffa09f86f4 moved ver info 5 spaces to the right 10 years ago
Alex Borro 2bbb68be8a Fix calculation of BAL grid fitting into the bed
The previous calc was wrong. Between N points there are only N-1 gaps,
not N.

So changing AUTO_BED_LEVELING_GRID_POINTS to
(AUTO_BED_LEVELING_GRID_POINTS-1)
10 years ago
Bo Herrmannsen 590caafa2d changed ver info 10 years ago
Bo Herrmannsen 3bb9b31515 changed boot logo a bit to test if fat wall goes away 10 years ago
Steffen Vogel da192c521f Merge pull request #1333 from andrewsil1/development
Fix grammar/typos in new Configuration.h option
10 years ago
Erik van der Zalm 3a30d45c2e Revert "issue 968 for dev branch" 10 years ago
andrewsil1 269ec9f87f Fix grammar/typos in new Configuration.h option
(For the SLOW_PWM_HEATERS option)
10 years ago
Steffen Vogel 8d7bfd03d8 moved/renamed documentation stuff to top-level directory 10 years ago
Bo Herrmannsen 3c9e6b7b62 added link for pic to hex converter 10 years ago
Bo Herrmannsen 0e760274bd changed reprap logo to marlin logo 10 years ago
Bo Herrmannsen b291a422e9 added square png version of logo
406*406 pixels
10 years ago
Luis E Alvarado 7ae548cf34 Update Marlin Firmware URL 10 years ago
Erik van der Zalm 8f9067faa6 Added marlin logos. (Designed by Ahmet Cem TURAN) 10 years ago
Bo Herrmannsen addf52fd4a Merge pull request #1328 from DinoMesina/development
Some corrections and new features
10 years ago
Dino Del Favero 5cfe13f240 Correct some mistakes 10 years ago
Dino Del Favero c7e2d73039 Merge branch 'development'
ok
10 years ago
Alex Borro 422a958a34 Fix CoreXY speed calculation
For cartesian bots, the X_AXIS is the real X movement and same for
Y_AXIS.
But for corexy bots, that is not true. The "X_AXIS" and "Y_AXIS" motors
(that should be named to A_AXIS
and B_AXIS) cannot be used for X and Y length, because A=X+Y and B=X-Y.
So we need to create other 2 "AXIS", named X_HEAD and Y_HEAD, meaning
the real displacement of the Head.
Having the real displacement of the head, we can calculate the total
movement length and apply the desired speed.
10 years ago
Dino Del Favero 038fccd7a1 I have added some code in the "temperature.cpp" for have the possibility of control the time of the states with the heater drived by relays, with this feature now it is possible use PID function in conjunction with relay to control the temperature. I have made some tests and the temperature stay always in the range of +-1°C from the setted temp.
There is the possibility of turn on this features adding "#define SLOW_PWM_HEATERS" in Configuration.h
10 years ago
DinoMesina 6730335657 Update Configuration.h 10 years ago
Bo Herrmannsen 4ffecdbf7d Merge pull request #1313 from wgm4321/Development
Re-enable filament menu with recalc fix when enabling/disabling mm3
10 years ago
Steffen Vogel 672f764b4d replaced ASCII GPL v3 license by markdown version
moved new COPYING file to top-level directory to make it more visible and remove clutter from Marlin subduer
10 years ago
Steffen Vogel f25e793cff rename stepper lookup table scipt to be consistent with termistor lookup table script 10 years ago
Steffen Vogel df17a6a1b4 fix #1305 by proposed workaround (thanks gaby64) 10 years ago
Steffen Vogel f7e65935fb make use of power operator 10 years ago
Steffen Vogel 4e02aff9b5 automatically determine min/max temp for terminator 10 years ago
Steffen Vogel 81363bc441 more cleanups 10 years ago
Steffen Vogel 95f4a55820 refactored termistor table calculation to be in line with wikipedia's article about Steinhart-Hart coefficients 10 years ago
Steffen Vogel 21205cc3d8 more cleanups in the termistorTable generation script 10 years ago
Steffen Vogel fb0996b5db improved output aligment and precision 10 years ago
Steffen Vogel 538231edfd cosmetic whitespace cleanup and comments added/updated 10 years ago
wgm4321 067b509479 Re-enable filament menu with recalc fix when enabling/disabling mm3 10 years ago
wgm4321 a19f2f8ae7 Disable volumetric menu item due to missing recalc of of multipliers when enabled/disabled 10 years ago
wgm4321 f24dda9700 Revert "Make sure volumetric multipliers are recalc'ed during menu enable/disable of mm3"
This reverts commit dd7e4ee97f.
10 years ago
wgm4321 ec4681ab6b Revert "Add "Detailed Z Probe" menu item with ABL is defined."
This reverts commit 2b9722f387.
10 years ago
wgm4321 dd7e4ee97f Make sure volumetric multipliers are recalc'ed during menu enable/disable of mm3 10 years ago
wgm4321 2b9722f387 Add "Detailed Z Probe" menu item with ABL is defined. 10 years ago
Dan Royer 9472bbe51d issue 968 for dev branch
try, try again.

If 'OK' is garbled on sending PC won't receive it.  Both machines will
wait on each other forever.  This resends OK if nothing is heard from PC
for a while to avoid this bad case.
10 years ago
alexborro d2b6e62996 Merge pull request #1309 from philfifi/fix_temp_runaway
temp runaway: proper cast to prevent any overflow.
10 years ago
Philippe L 30248214c7 temp runaway: proper cast to prevent any overflow. 10 years ago