872 Commits (0385acea7a99b6de654162719e40a1eb5635febf)

Author SHA1 Message Date
Scott Lahteine 27d70599d4 Change openFile default to "not-push" instead of "do-replace" 9 years ago
Scott Lahteine 0b8ef5eba6 Split get_command into units, rename to get_available_commands 9 years ago
Scott Lahteine 545f7997ea Continue on empty lines instead of returning 9 years ago
Scott Lahteine 3dcf6d42ff Don't store escaped serial characters if comment_mode 9 years ago
Scott Lahteine 5f8e52aefb Minor cleanup to command dispatcher 9 years ago
Scott Lahteine f1ed310322 Add NUMERIC compare macros to simplify code 9 years ago
jbrazio 443e6d26fe Formatted multi-line comments 9 years ago
Scott Lahteine e4039a9b5b Merge pull request #3250 from esenapaj/patch-1
Fix typo
9 years ago
Scott Lahteine cd4c3e90bc Send a busy signal every 10 seconds instead of every 2 9 years ago
Scott Lahteine 26168676e7 Merge pull request #3246 from thinkyhead/rc_fix_numeric_filenames
Fix: current_command_args skips digits at the front
9 years ago
esenapaj f54315c728 Fix typo
These are salvaged from closed-PR #3216.
9 years ago
Scott Lahteine f423716c6a Fix: current_command_args skips digits at the front
Closes #3245
9 years ago
Scott Lahteine 18de9f55ac Merge pull request #3242 from thinkyhead/rc_epatel_mesh_fixes
Updated Mesh Bed Leveling
9 years ago
Scott Lahteine 3a1e6b1752 Merge pull request #3243 from AnHardt/homed
axis_known_position -> axis_homed
9 years ago
AnHardt 94962ee678 axis_known_position -> axis_homed
In all these cases we want the axis to be homed. If we could have lost
some steps is secondary.

Reenables homing seperate axis with DISABLE_X / DISABLE_Y true.
9 years ago
Edward Patel 14afe1a017 Move to Z=0 for G28 when using Manual Bed Leveling
copy of 406992f9dd
9 years ago
Edward Patel c606ed447a Add "G29 S4" to fine tune Z level for Mesh Bed Leveling.
Also add mbl.z_offset to the EEPROM, bumping the version to V23.
9 years ago
Scott Lahteine 5d8036e554 Code cleanup around MOTOR_CURRENT_PWM options 9 years ago
Scott Lahteine 0da744b7b0 Further cleanup of comments, partial Doxygen-style
Following up on #3231
9 years ago
Scott Lahteine 4823791eb0 Merge pull request #3228 from esenapaj/patch-1
Fix spelling
9 years ago
jbrazio 5e5d250832 Added gplv3 header to all Marlin files 9 years ago
esenapaj 89a845659a Fix spelling
PROBABLE ->PROBEABLE
This is follow-up to #3069?
9 years ago
Scott Lahteine af32a7d5d6 M120/M121 also set endstops non-homing state 9 years ago
Scott Lahteine 04fa9d4f47 Make Autotune options into Menu Edit Items 9 years ago
WPBack e3f583a3be Fixes for PID AutoTune from menu
Fixes for #3189

Setting a temp is still missing
9 years ago
WPBack 3b3e8a02b5 Initial implementation of PID Autotune Menu Items
Adds the parameter U to M303. If U1 is included , it will use the
PID-values from the auto-tune.
9 years ago
Scott Lahteine c5857f96c8 Merge pull request #3182 from thinkyhead/rcbugfix_printrboard_revf
Add support for Printrboard RevF
9 years ago
Scott Lahteine f774420488 Merge pull request #3196 from thinkyhead/rc_controllerfan_bug
Make DISABLE_INACTIVE_X, etc., true if missing
9 years ago
AnHardt 1c6a16d5bb Send position updates to RH
Send position updates to RH where RH can not know the end position.

For example after G28 RepetierHost assumes to be at the homing-point,
but with a servo probe we are much higher. Now the RH-software-endstops
will prevent us from going down (if activated). With this patch the
internal position of RH is updated with `current_position[]`.
9 years ago
AnHardt 6486e8b74a Call buzz() directly from M428 9 years ago
Scott Lahteine b1a3a95ad4 Tweak controllerFan to save a cycle or two 9 years ago
Scott Lahteine 10caee2b7c Merge pull request #3187 from AnHardt/target_extruder_number
Fix extrudernum in MSG_INVALID_EXTRUDER
9 years ago
Scott Lahteine 1cc316f1fd Merge pull request #3082 from thinkyhead/updated_2820
This is quite comprehensive. If probes are disabled in any case when they shouldn't be, I'm sure we will hear about it soon.
9 years ago
Scott Lahteine 7bf5d117e7 Merge pull request #3069 from thinkyhead/rc_delta_compat_m48
Delta-compatible extensions to M48
9 years ago
Scott Lahteine 06332f20be Merge pull request #3113 from jbrazio/bugfix/3061-stop-print-time-counter
Stop print timer with M105/M109
9 years ago
AnHardt 338b69c24b Fix extrudernum in MSG_INVALID_EXTRUDER
SERIAL_ECHO is not very good in printing uint8_t - so cast. to int.
9 years ago
AnHardt b39b54031b Fix KEEPALIVE_STATE
Add return to NOT_BUSY for M105
Replace WAIT_FOR_USER with PAUSED_FOR_USER

Add Travis test for FILAMENTCHANGEENABLE
9 years ago
Scott Lahteine 41145e6e81 Patch drain_queued_commands_P
Fix a SNAFU that should have been caught in #3012
9 years ago
Scott Lahteine 59483221d5 Move stepper DAC to a separate file 9 years ago
Scott Lahteine 5d0570cea0 Make digitalPotWrite depend on HAS_DIGIPOTSS 9 years ago
Scott Lahteine f96bc03081 Add M907-M910 g-codes support for Printrbot Rev. F 9 years ago
Scott Lahteine cf7c444aff Apply unknown_position_error elsewhere 9 years ago
Scott Lahteine eda5190581 Check for known position in `M48` 9 years ago
Scott Lahteine 68085ca855 Updated M48 friendly for DELTA
Partial implementation with reference to MarlinFirmware/Marlin#3011
9 years ago
Scott Lahteine 38b0082bf2 Additional tweaks to M42 exit conditions 9 years ago
Scott Lahteine 4bbea5124d Support for multiple PWM fans 9 years ago
Scott Lahteine 637cc03686 Fix M109 so it won't wait for cooling
Addressing issue #2767
9 years ago
AnHardt 3f45a1acf9 Check probes only when deployed
Aim: Test probes in update_endstops only when activated

Changes:
Configurations
 Add define for FIX_MOUNTED_PROBE to handle the situation where formerly ENDSTOPS_ONLY_FOR_HOMING had to be set, or lowering the nozzle below Z_PROBE_OFFSET_FROM_EXTRUDER could give an "endstop hit" message.
 Add define for Z_MIN_PROBE_USES_Z_MIN_ENDSTOP_PIN to indicate a common situation, that we have a probe but it is connected to an endstop pin
 Add some comments
 Shift some entries to have related things together.

Conditionals.h
 We have a probe (HAS_Z_MIN_PROBE) if one of the pins is defined AND one of the probes is defined.

SanityCheck.h
 Add some tests if the probe is connected and if we have defined a probe.

stepper.cpp
 Changes to test the probe only when it is deployed (z_probe_is_active).
 Test update_endstops() when the probe is deployed.

MarlinMain.cpp
 a. set and reset z_probe_is_active in deploy_z_probe(), stow_z_probe() and dock_sled()
 b. set and reset z_probe_is_active in the case a z-servo is moved to a defined position. The only remaining unhandled servo move is in M280 where we do not end in a defined position. If you want to handle a probe use M401/402
 c. skip deploying/stowing when already deployed/stowed in the dedicated deploy/stow functions.
 d. Handle the new FIX_MOUNTED_PROBE in parallel to a servo driven probe/endstop.

 To do: In another PR. handle all probes in deploy/stow_z_probe.
 Sort out SERVO_LEVELING vs. HAS_SERVO_ENDSTOPS.
9 years ago
Scott Lahteine 4634feaeab Merge pull request #3012 from thinkyhead/fix_command_injection
Use a serial line buffer to prevent queue corruption
9 years ago
Scott Lahteine 963a92ceda Patch idle forevermore 9 years ago