# Readme
|
||||
|
||||
These configurations activate many of the new advanced features of the Marlin firmware:
|
||||
|
||||
* Auto Calibration
|
||||
* Auto Bed Leveling
|
||||
* Pause & Filament Change
|
||||
|
||||
**Important**: Before doing anything else after updating the firmware, go to `Configuration > Advanced Settings > Initialize EEPROM` to get rid of old configurations.
|
||||
|
||||
After that you should connect the Z-Probe and start `Configuration > Delta Calibration > Auto Calibration`. When it's done don't forget to also do `Configuration > Delta Calibration > Store Settings` to make it permanent.
|
||||
|
||||
You should also do a `Motion > Bed Leveling > Level bed` followed by `Store Settings` to ensure a perfect leveling.
|
||||
|
||||
Please do a manual paper test (moving the nozzle slowly down to Z0 and checking with a piece of paper). If it's not perfect, use `Configuration > Advanced Settings > Probe Z Offset` to correct the difference and execute the calibration again.
|
||||
|
||||
**Also Important**: if you value your Z-Probe do NOT execute `Configuration > Delta Configuration > Probe Z-offset` - This can destroy the Z-Probe, see issue [#11337](https://github.com/MarlinFirmware/Marlin/issues/11337).
|
||||
|
||||
# Select the Configuration
|
||||
|
||||
**Please select the correct values at the start of the Configuration.h file**
|
||||
|
||||
The Kossel comes in 3 versions:
|
||||
|
||||
* Pulley
|
||||
* Linear
|
||||
* Linear Plus
|
||||
|
||||
Pulley and Linear use the same configuration, the Linear Plus is bigger and uses slightly different configurations.
|
||||
|
||||
Typically the probes for the Anycubic Delta Kossel printers come in two different versions.
|
||||
|
||||
* Version 1: Z Probe Offset of -19.0mm
|
||||
|
||||
![Version 1 Probe](images/Version1Probe.jpg)
|
||||
|
||||
* Version 2: Z Probe Offset of -16.8mm
|
||||
|
||||
![Version 2 Probe](images/Version2Probe.jpg)
|
||||
|
||||
If you select the `ANYCUBIC_PROBE_VERSION 0`: It's very important to follow the correct procedure to set it up after flashing the firmware, otherwise you might damage the printer by ramming the nozzle into the buildplate:
|
||||
|
||||
* `Configuration > Advanced Settings > Initialize EEPROM`
|
||||
* `Motion > Move Axis > Soft Endstops` : `Off`
|
||||
* Auto Home and slowly move the nozzle down until it barely touches the bed. (Do a paper-test: A normal sheet of paper should just feel the drag of the nozzle) and note this number.
|
||||
* Subtract this number from the value in `Configuration > Delta Calibration > Delta Settings > Height`. (If it's negative, add it).
|
||||
* Save and try the paper test again to verify your height.
|
||||
* `Configuration > Store Settings`
|
||||
* Motion > Bed Leveling (using paper test)
|