Fix chamber temperature measurement (#13350)

2.0.x
MoellerDi 6 years ago committed by Scott Lahteine
parent 12503fce06
commit c36989c39e

@ -219,6 +219,7 @@ hotend_info_t Temperature::temp_hotend[HOTENDS]; // = { 0 }
#endif // HAS_HEATED_BED
#if HAS_TEMP_CHAMBER
chamber_info_t Temperature::temp_chamber; // = { 0 }
#if HAS_HEATED_CHAMBER
#ifdef CHAMBER_MINTEMP
int16_t Temperature::mintemp_raw_CHAMBER = HEATER_CHAMBER_RAW_LO_TEMP;
@ -226,7 +227,6 @@ hotend_info_t Temperature::temp_hotend[HOTENDS]; // = { 0 }
#ifdef CHAMBER_MAXTEMP
int16_t Temperature::maxtemp_raw_CHAMBER = HEATER_CHAMBER_RAW_HI_TEMP;
#endif
chamber_info_t temp_chamber; // = { 0 }
#if WATCH_CHAMBER
heater_watch_t Temperature::watch_chamber = { 0 };
millis_t Temperature::next_chamber_check_ms;
@ -1993,7 +1993,7 @@ void Temperature::disable_all_heaters() {
#endif
#endif
#if HAS_TEMP_CHAMBER
#if HAS_HEATED_CHAMBER
temp_chamber.target = 0;
temp_chamber.soft_pwm_amount = 0;
#if HAS_HEATED_CHAMBER
@ -2264,13 +2264,17 @@ void Temperature::readings_ready() {
if (bed_on && BEDCMP(mintemp_raw_BED, temp_bed.raw)) min_temp_error(-1);
#endif
#if HAS_TEMP_CHAMBER
#if TEMPDIR(BED) < 0
#if HAS_HEATED_CHAMBER
#if TEMPDIR(CHAMBER) < 0
#define CHAMBERCMP(A,B) ((A)<=(B))
#else
#define CHAMBERCMP(A,B) ((A)>=(B))
#endif
const bool chamber_on = (temp_chamber.target > 0) || (temp_chamber.soft_pwm_amount > 0);
const bool chamber_on = (temp_chamber.target > 0)
#if ENABLED(PIDTEMPCHAMBER)
|| (temp_chamber.soft_pwm_amount > 0)
#endif
;
if (CHAMBERCMP(temp_chamber.raw, maxtemp_raw_CHAMBER)) max_temp_error(-2);
if (chamber_on && CHAMBERCMP(mintemp_raw_CHAMBER, temp_chamber.raw)) min_temp_error(-2);