@ -292,6 +292,43 @@
|
|
|
|
|
#define EXTRUDE_MINTEMP 150
|
|
|
|
|
#define EXTRUDE_MAXLENGTH (X_MAX_LENGTH+Y_MAX_LENGTH) //prevent extrusion of very large distances.
|
|
|
|
|
|
|
|
|
|
/*================== Thermal Runaway Protection ==============================
|
|
|
|
|
This is a feature to protect your printer from burn up in flames if it has
|
|
|
|
|
a thermistor coming off place (this happened to a friend of mine recently and
|
|
|
|
|
motivated me writing this feature).
|
|
|
|
|
|
|
|
|
|
The issue: If a thermistor come off, it will read a lower temperature than actual.
|
|
|
|
|
The system will turn the heater on forever, burning up the filament and anything
|
|
|
|
|
else around.
|
|
|
|
|
|
|
|
|
|
After the temperature reaches the target for the first time, this feature will
|
|
|
|
|
start measuring for how long the current temperature stays below the target
|
|
|
|
|
minus _HYSTERESIS (set_temperature - THERMAL_RUNAWAY_PROTECTION_HYSTERESIS).
|
|
|
|
|
|
|
|
|
|
If it stays longer than _PERIOD, it means the thermistor temperature
|
|
|
|
|
cannot catch up with the target, so something *may be* wrong. Then, to be on the
|
|
|
|
|
safe side, the system will he halt.
|
|
|
|
|
|
|
|
|
|
Bear in mind the count down will just start AFTER the first time the
|
|
|
|
|
thermistor temperature is over the target, so you will have no problem if
|
|
|
|
|
your extruder heater takes 2 minutes to hit the target on heating.
|
|
|
|
|
|
|
|
|
|
*/
|
|
|
|
|
// If you want to enable this feature for all your extruder heaters,
|
|
|
|
|
// uncomment the 2 defines below:
|
|
|
|
|
|
|
|
|
|
// Parameters for all extruder heaters
|
|
|
|
|
//#define THERMAL_RUNAWAY_PROTECTION_PERIOD 40 //in seconds
|
|
|
|
|
//#define THERMAL_RUNAWAY_PROTECTION_HYSTERESIS 4 // in degree Celsius
|
|
|
|
|
|
|
|
|
|
// If you want to enable this feature for your bed heater,
|
|
|
|
|
// uncomment the 2 defines below:
|
|
|
|
|
|
|
|
|
|
// Parameters for the bed heater
|
|
|
|
|
//#define THERMAL_RUNAWAY_PROTECTION_BED_PERIOD 20 //in seconds
|
|
|
|
|
//#define THERMAL_RUNAWAY_PROTECTION_BED_HYSTERESIS 2 // in degree Celsius
|
|
|
|
|
//===========================================================================
|
|
|
|
|
|
|
|
|
|
//===========================================================================
|
|
|
|
|