Configs for Prusa i3 Pro B GT2560 Rev.A Plus ()

One without probe and one with BLTOUCH.
2.0.x
Scott Lahteine committed by GitHub
parent b5e92f4f90
commit 8558264514
No known key found for this signature in database
GPG Key ID: 4AEE18F83AFDEB23

@ -0,0 +1,39 @@
These are example configurations for the low-cost [Acrylic Prusa I3 pro B 3D Printer DIY kit](http://www.geeetech.com/acrylic-geeetech-prusa-i3-pro-b-3d-printer-diy-kit-p-917.html) and the [3DTouch auto bed leveling sensor](http://www.geeetech.com/geeetech-3dtouch-auto-bed-leveling-sensor-for-3d-printer-p-1010.html) based on:
- `../GT2560/`
- [Marlin 1.1.4 With 3DTouch / BLTouch for i3 Pro B](https://www.geeetech.com/forum/viewtopic.php?t=19846)
The main characteristics of these configurations are:
- The defined motherboard is `BOARD_GT2560_REV_A_PLUS`.
- Travel limits are adjusted to the printer bed size and position.
- An example `SKEW_CORRECTION` for a particular printer is enabled. See comments below about how to adjust it to a particular printer.
- Using the LCD controller for bed leveling is enabled.
- `PROBE_MANUALLY` is enabled, which *provides a means to do "Auto" Bed Leveling without a probe*.
- The `LEVEL_BED_CORNERS` option for manual bed adjustment is enabled.
- Bilinear bed leveling is enabled, the boundaries for probing are adjusted to the glass size, and extrapolation is enabled.
- `PRINTCOUNTER` is enabled, in order to track statistical data.
- `INDIVIDUAL_AXIS_HOMING_MENU` is enabled, which adds individual axis homing items (Home X, Home Y, and Home Z) to the LCD menu.
- The speaker is enabled for the UI feedback.
- `bltouch` variant:
- `USE_ZMAX_PLUG` is enabled. See comments about connections below.
- Heaters and fans are turned off when probing.
- Multiple probing is set to 3.
# First-time configuration
## Skew factor
The skew factor must be adjusted for each printer:
- First, uncomment `#define XY_SKEW_FACTOR 0.0`, compile and upload the firmware.
- Then, print [YACS (Yet Another Calibration Square)](https://www.thingiverse.com/thing:2563185). Hint, scale it considering a margin for brim (if used). The larger, the better to make error measurements.
- Measure the printed part according to the comments in the example configuration file, and set `XY_DIAG_AC`, `XY_DIAG_BD` and `Y_SIDE_AD`.
- Last, comment `#define XY_SKEW_FACTOR 0.0` again, compile and upload.
## 3DTouch auto leveling sensor
- Print a suitable mount to attach the sensor to the printer. The example configuration file is adjusted to http://www.geeetech.com/wiki/images/6/61/3DTouch_auto_leveling_sensor-1.zip
- Unlike suggested in [geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor](https://www.geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor), the existing end stop switch is expected to be kept connected to Z_MIN. So, the sensor is to be connected to Z_MAX, according to Marlin's default settings. Furthermore, GT2560-A+ provides a connector for the servo next to thermistor connectors (see [GT2560](https://www.geeetech.com/wiki/images/thumb/4/45/GT2560_wiring.jpg/700px-GT2560_wiring.jpg) and [GT2560-A+](http://i.imgur.com/E0t34VU.png)).
- Be careful to respect the polarity of the sensor when connecting it to the GT2560-A+. Unlike end stops, reversing the connection will prevent the sensor from working properly.
- [Test](http://www.geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor#Testing) and [calibrate](https://www.geeetech.com/wiki/index.php/3DTouch_Auto_Leveling_Sensor#Calibration) the sensor.