Shut down autotemp in disable_all_heaters

2.0.x
Scott Lahteine 8 years ago
parent acec237092
commit 6854f08d22

@ -141,7 +141,7 @@ script:
- restore_configs
- opt_enable NUM_SERVOS Z_ENDSTOP_SERVO_NR Z_SERVO_ANGLES DEACTIVATE_SERVOS_AFTER_MOVE
- opt_enable AUTO_BED_LEVELING_3POINT DEBUG_LEVELING_FEATURE EEPROM_SETTINGS EEPROM_CHITCHAT
- opt_enable_adv EXTENDED_CAPABILITIES_REPORT AUTO_REPORT_TEMPERATURES
- opt_enable_adv EXTENDED_CAPABILITIES_REPORT AUTO_REPORT_TEMPERATURES AUTOTEMP
- build_marlin
#
# Test MESH_BED_LEVELING feature, with LCD

@ -5762,10 +5762,6 @@ inline void gcode_M31() {
SERIAL_ECHO_START;
SERIAL_ECHOLNPAIR("Print time: ", buffer);
#if ENABLED(AUTOTEMP)
thermalManager.autotempShutdown();
#endif
}
#if ENABLED(SDSUPPORT)

@ -25,9 +25,10 @@
*/
#include "Marlin.h"
#include "ultralcd.h"
#include "temperature.h"
#include "thermistortables.h"
#include "ultralcd.h"
#include "planner.h"
#include "language.h"
#if ENABLED(HEATER_0_USES_MAX6675)
@ -1288,6 +1289,11 @@ void Temperature::init() {
#endif // THERMAL_PROTECTION_HOTENDS || THERMAL_PROTECTION_BED
void Temperature::disable_all_heaters() {
#if ENABLED(AUTOTEMP)
planner.autotemp_enabled = false;
#endif
HOTEND_LOOP() setTargetHotend(0, e);
setTargetBed(0);

@ -27,7 +27,6 @@
#ifndef TEMPERATURE_H
#define TEMPERATURE_H
#include "planner.h"
#include "thermistortables.h"
#include "MarlinConfig.h"
@ -418,16 +417,6 @@ class Temperature {
*/
static void updatePID();
#if ENABLED(AUTOTEMP)
static void autotempShutdown() {
if (planner.autotemp_enabled) {
planner.autotemp_enabled = false;
if (degTargetHotend(EXTRUDER_IDX) > planner.autotemp_min)
setTargetHotend(0, EXTRUDER_IDX);
}
}
#endif
#if ENABLED(BABYSTEPPING)
static void babystep_axis(const AxisEnum axis, const int distance) {

Loading…
Cancel
Save