@ -37,6 +37,21 @@
|
|
|
|
|
#include "../../module/endstops.h"
|
|
|
|
|
#include "../../feature/bedlevel/bedlevel.h"
|
|
|
|
|
|
|
|
|
|
#if !AXIS_CAN_CALIBRATE(X)
|
|
|
|
|
#undef CALIBRATION_MEASURE_LEFT
|
|
|
|
|
#undef CALIBRATION_MEASURE_RIGHT
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
#if !AXIS_CAN_CALIBRATE(Y)
|
|
|
|
|
#undef CALIBRATION_MEASURE_FRONT
|
|
|
|
|
#undef CALIBRATION_MEASURE_BACK
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
#if !AXIS_CAN_CALIBRATE(Z)
|
|
|
|
|
#undef CALIBRATION_MEASURE_AT_TOP_EDGES
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
|
* G425 backs away from the calibration object by various distances
|
|
|
|
|
* depending on the confidence level:
|
|
|
|
@ -207,42 +222,52 @@ inline float measure(const AxisEnum axis, const int dir, const bool stop_state,
|
|
|
|
|
inline void probe_side(measurements_t &m, const float uncertainty, const side_t side, const bool probe_top_at_edge=false) {
|
|
|
|
|
const xyz_float_t dimensions = CALIBRATION_OBJECT_DIMENSIONS;
|
|
|
|
|
AxisEnum axis;
|
|
|
|
|
float dir;
|
|
|
|
|
float dir = 1;
|
|
|
|
|
|
|
|
|
|
park_above_object(m, uncertainty);
|
|
|
|
|
|
|
|
|
|
switch (side) {
|
|
|
|
|
case TOP: {
|
|
|
|
|
const float measurement = measure(Z_AXIS, -1, true, &m.backlash[TOP], uncertainty);
|
|
|
|
|
m.obj_center.z = measurement - dimensions.z / 2;
|
|
|
|
|
m.obj_side[TOP] = measurement;
|
|
|
|
|
return;
|
|
|
|
|
}
|
|
|
|
|
case RIGHT: axis = X_AXIS; dir = -1; break;
|
|
|
|
|
case FRONT: axis = Y_AXIS; dir = 1; break;
|
|
|
|
|
case LEFT: axis = X_AXIS; dir = 1; break;
|
|
|
|
|
case BACK: axis = Y_AXIS; dir = -1; break;
|
|
|
|
|
#if AXIS_CAN_CALIBRATE(Z)
|
|
|
|
|
case TOP: {
|
|
|
|
|
const float measurement = measure(Z_AXIS, -1, true, &m.backlash[TOP], uncertainty);
|
|
|
|
|
m.obj_center.z = measurement - dimensions.z / 2;
|
|
|
|
|
m.obj_side[TOP] = measurement;
|
|
|
|
|
return;
|
|
|
|
|
}
|
|
|
|
|
#endif
|
|
|
|
|
#if AXIS_CAN_CALIBRATE(X)
|
|
|
|
|
case LEFT: axis = X_AXIS; break;
|
|
|
|
|
case RIGHT: axis = X_AXIS; dir = -1; break;
|
|
|
|
|
#endif
|
|
|
|
|
#if AXIS_CAN_CALIBRATE(Y)
|
|
|
|
|
case FRONT: axis = Y_AXIS; break;
|
|
|
|
|
case BACK: axis = Y_AXIS; dir = -1; break;
|
|
|
|
|
#endif
|
|
|
|
|
default: return;
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
if (probe_top_at_edge) {
|
|
|
|
|
// Probe top nearest the side we are probing
|
|
|
|
|
current_position[axis] = m.obj_center[axis] + (-dir) * (dimensions[axis] / 2 - m.nozzle_outer_dimension[axis]);
|
|
|
|
|
calibration_move();
|
|
|
|
|
m.obj_side[TOP] = measure(Z_AXIS, -1, true, &m.backlash[TOP], uncertainty);
|
|
|
|
|
m.obj_center.z = m.obj_side[TOP] - dimensions.z / 2;
|
|
|
|
|
#if AXIS_CAN_CALIBRATE(Z)
|
|
|
|
|
// Probe top nearest the side we are probing
|
|
|
|
|
current_position[axis] = m.obj_center[axis] + (-dir) * (dimensions[axis] / 2 - m.nozzle_outer_dimension[axis]);
|
|
|
|
|
calibration_move();
|
|
|
|
|
m.obj_side[TOP] = measure(Z_AXIS, -1, true, &m.backlash[TOP], uncertainty);
|
|
|
|
|
m.obj_center.z = m.obj_side[TOP] - dimensions.z / 2;
|
|
|
|
|
#endif
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
// Move to safe distance to the side of the calibration object
|
|
|
|
|
current_position[axis] = m.obj_center[axis] + (-dir) * (dimensions[axis] / 2 + m.nozzle_outer_dimension[axis] / 2 + uncertainty);
|
|
|
|
|
calibration_move();
|
|
|
|
|
if (AXIS_CAN_CALIBRATE(X) && axis == X_AXIS || AXIS_CAN_CALIBRATE(Y) && axis == Y_AXIS) {
|
|
|
|
|
// Move to safe distance to the side of the calibration object
|
|
|
|
|
current_position[axis] = m.obj_center[axis] + (-dir) * (dimensions[axis] / 2 + m.nozzle_outer_dimension[axis] / 2 + uncertainty);
|
|
|
|
|
calibration_move();
|
|
|
|
|
|
|
|
|
|
// Plunge below the side of the calibration object and measure
|
|
|
|
|
current_position.z = m.obj_side[TOP] - CALIBRATION_NOZZLE_TIP_HEIGHT * 0.7;
|
|
|
|
|
calibration_move();
|
|
|
|
|
const float measurement = measure(axis, dir, true, &m.backlash[side], uncertainty);
|
|
|
|
|
m.obj_center[axis] = measurement + dir * (dimensions[axis] / 2 + m.nozzle_outer_dimension[axis] / 2);
|
|
|
|
|
m.obj_side[side] = measurement;
|
|
|
|
|
// Plunge below the side of the calibration object and measure
|
|
|
|
|
current_position.z = m.obj_side[TOP] - (CALIBRATION_NOZZLE_TIP_HEIGHT) * 0.7f;
|
|
|
|
|
calibration_move();
|
|
|
|
|
const float measurement = measure(axis, dir, true, &m.backlash[side], uncertainty);
|
|
|
|
|
m.obj_center[axis] = measurement + dir * (dimensions[axis] / 2 + m.nozzle_outer_dimension[axis] / 2);
|
|
|
|
|
m.obj_side[side] = measurement;
|
|
|
|
|
}
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
/**
|
|
|
|
@ -252,7 +277,7 @@ inline void probe_side(measurements_t &m, const float uncertainty, const side_t
|
|
|
|
|
* uncertainty in - How far away from the calibration object to begin probing
|
|
|
|
|
*/
|
|
|
|
|
inline void probe_sides(measurements_t &m, const float uncertainty) {
|
|
|
|
|
#ifdef CALIBRATION_MEASURE_AT_TOP_EDGES
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_AT_TOP_EDGES)
|
|
|
|
|
constexpr bool probe_top_at_edge = true;
|
|
|
|
|
#else
|
|
|
|
|
// Probing at the exact center only works if the center is flat. Probing on a washer
|
|
|
|
@ -261,18 +286,18 @@ inline void probe_sides(measurements_t &m, const float uncertainty) {
|
|
|
|
|
probe_side(m, uncertainty, TOP);
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
#ifdef CALIBRATION_MEASURE_RIGHT
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_RIGHT)
|
|
|
|
|
probe_side(m, uncertainty, RIGHT, probe_top_at_edge);
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
#ifdef CALIBRATION_MEASURE_FRONT
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_FRONT)
|
|
|
|
|
probe_side(m, uncertainty, FRONT, probe_top_at_edge);
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
#ifdef CALIBRATION_MEASURE_LEFT
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_LEFT)
|
|
|
|
|
probe_side(m, uncertainty, LEFT, probe_top_at_edge);
|
|
|
|
|
#endif
|
|
|
|
|
#ifdef CALIBRATION_MEASURE_BACK
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_BACK)
|
|
|
|
|
probe_side(m, uncertainty, BACK, probe_top_at_edge);
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
@ -313,7 +338,9 @@ inline void probe_sides(measurements_t &m, const float uncertainty) {
|
|
|
|
|
#if ENABLED(CALIBRATION_REPORTING)
|
|
|
|
|
inline void report_measured_faces(const measurements_t &m) {
|
|
|
|
|
SERIAL_ECHOLNPGM("Sides:");
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Top: ", m.obj_side[TOP]);
|
|
|
|
|
#if AXIS_CAN_CALIBRATE(Z)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Top: ", m.obj_side[TOP]);
|
|
|
|
|
#endif
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_LEFT)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Left: ", m.obj_side[LEFT]);
|
|
|
|
|
#endif
|
|
|
|
@ -343,19 +370,25 @@ inline void probe_sides(measurements_t &m, const float uncertainty) {
|
|
|
|
|
|
|
|
|
|
inline void report_measured_backlash(const measurements_t &m) {
|
|
|
|
|
SERIAL_ECHOLNPGM("Backlash:");
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_LEFT)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Left: ", m.backlash[LEFT]);
|
|
|
|
|
#endif
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_RIGHT)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Right: ", m.backlash[RIGHT]);
|
|
|
|
|
#if AXIS_CAN_CALIBRATE(X)
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_LEFT)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Left: ", m.backlash[LEFT]);
|
|
|
|
|
#endif
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_RIGHT)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Right: ", m.backlash[RIGHT]);
|
|
|
|
|
#endif
|
|
|
|
|
#endif
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_FRONT)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Front: ", m.backlash[FRONT]);
|
|
|
|
|
#if AXIS_CAN_CALIBRATE(Y)
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_FRONT)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Front: ", m.backlash[FRONT]);
|
|
|
|
|
#endif
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_BACK)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Back: ", m.backlash[BACK]);
|
|
|
|
|
#endif
|
|
|
|
|
#endif
|
|
|
|
|
#if ENABLED(CALIBRATION_MEASURE_BACK)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Back: ", m.backlash[BACK]);
|
|
|
|
|
#if AXIS_CAN_CALIBRATE(Z)
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Top: ", m.backlash[TOP]);
|
|
|
|
|
#endif
|
|
|
|
|
SERIAL_ECHOLNPAIR(" Top: ", m.backlash[TOP]);
|
|
|
|
|
SERIAL_EOL();
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
@ -369,7 +402,7 @@ inline void probe_sides(measurements_t &m, const float uncertainty) {
|
|
|
|
|
#if HAS_Y_CENTER
|
|
|
|
|
SERIAL_ECHOLNPAIR_P(SP_Y_STR, m.pos_error.y);
|
|
|
|
|
#endif
|
|
|
|
|
SERIAL_ECHOLNPAIR_P(SP_Z_STR, m.pos_error.z);
|
|
|
|
|
if (AXIS_CAN_CALIBRATE(Z)) SERIAL_ECHOLNPAIR_P(SP_Z_STR, m.pos_error.z);
|
|
|
|
|
SERIAL_EOL();
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
@ -417,6 +450,7 @@ inline void calibrate_backlash(measurements_t &m, const float uncertainty) {
|
|
|
|
|
probe_sides(m, uncertainty);
|
|
|
|
|
|
|
|
|
|
#if ENABLED(BACKLASH_GCODE)
|
|
|
|
|
|
|
|
|
|
#if HAS_X_CENTER
|
|
|
|
|
backlash.distance_mm.x = (m.backlash[LEFT] + m.backlash[RIGHT]) / 2;
|
|
|
|
|
#elif ENABLED(CALIBRATION_MEASURE_LEFT)
|
|
|
|
@ -433,18 +467,18 @@ inline void calibrate_backlash(measurements_t &m, const float uncertainty) {
|
|
|
|
|
backlash.distance_mm.y = m.backlash[BACK];
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
backlash.distance_mm.z = m.backlash[TOP];
|
|
|
|
|
if (AXIS_CAN_CALIBRATE(Z)) backlash.distance_mm.z = m.backlash[TOP];
|
|
|
|
|
#endif
|
|
|
|
|
}
|
|
|
|
|
|
|
|
|
|
#if ENABLED(BACKLASH_GCODE)
|
|
|
|
|
// Turn on backlash compensation and move in all
|
|
|
|
|
// directions to take up any backlash
|
|
|
|
|
// allowed directions to take up any backlash
|
|
|
|
|
{
|
|
|
|
|
// New scope for TEMPORARY_BACKLASH_CORRECTION
|
|
|
|
|
TEMPORARY_BACKLASH_CORRECTION(all_on);
|
|
|
|
|
TEMPORARY_BACKLASH_SMOOTHING(0.0f);
|
|
|
|
|
const xyz_float_t move = { 3, 3, 3 };
|
|
|
|
|
const xyz_float_t move = { AXIS_CAN_CALIBRATE(X) * 3, AXIS_CAN_CALIBRATE(Y) * 3, AXIS_CAN_CALIBRATE(Z) * 3 };
|
|
|
|
|
current_position += move; calibration_move();
|
|
|
|
|
current_position -= move; calibration_move();
|
|
|
|
|
}
|
|
|
|
@ -482,26 +516,18 @@ inline void calibrate_toolhead(measurements_t &m, const float uncertainty, const
|
|
|
|
|
|
|
|
|
|
// Adjust the hotend offset
|
|
|
|
|
#if HAS_HOTEND_OFFSET
|
|
|
|
|
#if HAS_X_CENTER
|
|
|
|
|
hotend_offset[extruder].x += m.pos_error.x;
|
|
|
|
|
#endif
|
|
|
|
|
#if HAS_Y_CENTER
|
|
|
|
|
hotend_offset[extruder].y += m.pos_error.y;
|
|
|
|
|
#endif
|
|
|
|
|
hotend_offset[extruder].z += m.pos_error.z;
|
|
|
|
|
if (ENABLED(HAS_X_CENTER) && AXIS_CAN_CALIBRATE(X)) hotend_offset[extruder].x += m.pos_error.x;
|
|
|
|
|
if (ENABLED(HAS_Y_CENTER) && AXIS_CAN_CALIBRATE(Y)) hotend_offset[extruder].y += m.pos_error.y;
|
|
|
|
|
if (AXIS_CAN_CALIBRATE(Z)) hotend_offset[extruder].z += m.pos_error.z;
|
|
|
|
|
normalize_hotend_offsets();
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
// Correct for positional error, so the object
|
|
|
|
|
// is at the known actual spot
|
|
|
|
|
planner.synchronize();
|
|
|
|
|
#if HAS_X_CENTER
|
|
|
|
|
update_measurements(m, X_AXIS);
|
|
|
|
|
#endif
|
|
|
|
|
#if HAS_Y_CENTER
|
|
|
|
|
update_measurements(m, Y_AXIS);
|
|
|
|
|
#endif
|
|
|
|
|
update_measurements(m, Z_AXIS);
|
|
|
|
|
if (ENABLED(HAS_X_CENTER) && AXIS_CAN_CALIBRATE(X)) update_measurements(m, X_AXIS);
|
|
|
|
|
if (ENABLED(HAS_Y_CENTER) && AXIS_CAN_CALIBRATE(Y)) update_measurements(m, Y_AXIS);
|
|
|
|
|
if (AXIS_CAN_CALIBRATE(Z)) update_measurements(m, Z_AXIS);
|
|
|
|
|
|
|
|
|
|
sync_plan_position();
|
|
|
|
|
}
|
|
|
|
|