@ -414,7 +414,46 @@ const short temptable_52[][2] PROGMEM = {
|
|
|
|
|
};
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
|
|
|
|
|
#if (THERMISTORHEATER_0 == 55) || (THERMISTORHEATER_1 == 55) || (THERMISTORHEATER_2 == 55) || (THERMISTORBED == 55)
|
|
|
|
|
// 100k ATC Semitec 104GT-2 (Used on ParCan) (WITH 1kohm RESISTOR FOR PULLUP, R9 ON SANGUINOLOLU! NOT FOR 4.7kohm PULLUP! THIS IS NOT NORMAL!)
|
|
|
|
|
// Verified by linagee. Source: http://shop.arcol.hu/static/datasheets/thermistors.pdf
|
|
|
|
|
// Calculated using 1kohm pullup, voltage divider math, and manufacturer provided temp/resistance
|
|
|
|
|
// Advantage: More resolution and better linearity from 150C to 200C
|
|
|
|
|
const short temptable_52[][2] PROGMEM = {
|
|
|
|
|
{1*OVERSAMPLENR, 500},
|
|
|
|
|
{76*OVERSAMPLENR, 300},
|
|
|
|
|
{87*OVERSAMPLENR, 290},
|
|
|
|
|
{100*OVERSAMPLENR, 280},
|
|
|
|
|
{114*OVERSAMPLENR, 270},
|
|
|
|
|
{131*OVERSAMPLENR, 260},
|
|
|
|
|
{152*OVERSAMPLENR, 250},
|
|
|
|
|
{175*OVERSAMPLENR, 240},
|
|
|
|
|
{202*OVERSAMPLENR, 230},
|
|
|
|
|
{234*OVERSAMPLENR, 220},
|
|
|
|
|
{271*OVERSAMPLENR, 210},
|
|
|
|
|
{312*OVERSAMPLENR, 200},
|
|
|
|
|
{359*OVERSAMPLENR, 190},
|
|
|
|
|
{411*OVERSAMPLENR, 180},
|
|
|
|
|
{467*OVERSAMPLENR, 170},
|
|
|
|
|
{527*OVERSAMPLENR, 160},
|
|
|
|
|
{590*OVERSAMPLENR, 150},
|
|
|
|
|
{652*OVERSAMPLENR, 140},
|
|
|
|
|
{713*OVERSAMPLENR, 130},
|
|
|
|
|
{770*OVERSAMPLENR, 120},
|
|
|
|
|
{822*OVERSAMPLENR, 110},
|
|
|
|
|
{867*OVERSAMPLENR, 100},
|
|
|
|
|
{905*OVERSAMPLENR, 90},
|
|
|
|
|
{936*OVERSAMPLENR, 80},
|
|
|
|
|
{961*OVERSAMPLENR, 70},
|
|
|
|
|
{979*OVERSAMPLENR, 60},
|
|
|
|
|
{993*OVERSAMPLENR, 50},
|
|
|
|
|
{1003*OVERSAMPLENR, 40},
|
|
|
|
|
{1010*OVERSAMPLENR, 30},
|
|
|
|
|
{1015*OVERSAMPLENR, 20},
|
|
|
|
|
{1018*OVERSAMPLENR, 10},
|
|
|
|
|
{1020*OVERSAMPLENR, 0}
|
|
|
|
|
};
|
|
|
|
|
#endif
|
|
|
|
|
|
|
|
|
|
#define _TT_NAME(_N) temptable_ ## _N
|
|
|
|
|
#define TT_NAME(_N) _TT_NAME(_N)
|
|
|
|
|