Fix M421 AUTO_BED_LEVELING_BILINEAR and AUTO_BED_LEVELING_UBL

M421 was not connected up for AUTO_BED_LEVELING_BILINEAR.
M421 needed to migrate mesh data to new UBL EEPROM layout.
2.0.x
Roxy-3D 8 years ago committed by Roxy-3D
parent 3412950abc
commit 0423e93c42

@ -178,7 +178,7 @@
* M407 - Display measured filament diameter in millimeters. (Requires FILAMENT_WIDTH_SENSOR)
* M410 - Quickstop. Abort all planned moves.
* M420 - Enable/Disable Leveling (with current values) S1=enable S0=disable (Requires MESH_BED_LEVELING or ABL)
* M421 - Set a single Z coordinate in the Mesh Leveling grid. X<units> Y<units> Z<units> (Requires MESH_BED_LEVELING)
* M421 - Set a single Z coordinate in the Mesh Leveling grid. X<units> Y<units> Z<units> (Requires MESH_BED_LEVELING or AUTO_BED_LEVELING_UBL)
* M428 - Set the home_offset based on the current_position. Nearest edge applies.
* M500 - Store parameters in EEPROM. (Requires EEPROM_SETTINGS)
* M501 - Restore parameters from EEPROM. (Requires EEPROM_SETTINGS)
@ -7557,8 +7557,7 @@ void quickstop_stepper() {
}
#endif
#if ENABLED(MESH_BED_LEVELING)
#if ENABLED(MESH_BED_LEVELING)
/**
* M421: Set a single Mesh Bed Leveling Z coordinate
* Use either 'M421 X<linear> Y<linear> Z<linear>' or 'M421 I<xindex> J<yindex> Z<linear>'
@ -7628,7 +7627,34 @@ void quickstop_stepper() {
SERIAL_ERRORLNPGM(MSG_ERR_M421_PARAMETERS);
}
}
#elif ENABLED(AUTO_BED_LEVELING_UBL)
/**
* M421: Set a single Mesh Bed Leveling Z coordinate
*
* M421 I<xindex> J<yindex> Z<linear>
*/
inline void gcode_M421() {
int8_t px = 0, py = 0;
float z = 0;
bool hasI, hasJ, hasZ;
if ((hasI = code_seen('I'))) px = code_value_axis_units(X_AXIS);
if ((hasJ = code_seen('J'))) py = code_value_axis_units(Y_AXIS);
if ((hasZ = code_seen('Z'))) z = code_value_axis_units(Z_AXIS);
if (hasI && hasJ && hasZ) {
if (WITHIN(px, 0, UBL_MESH_NUM_Y_POINTS - 1) && WITHIN(py, 0, UBL_MESH_NUM_Y_POINTS - 1)) {
ubl.z_values[px][py] = z;
}
else {
SERIAL_ERROR_START;
SERIAL_ERRORLNPGM(MSG_ERR_MESH_XY);
}
}
else {
SERIAL_ERROR_START;
SERIAL_ERRORLNPGM(MSG_ERR_M421_PARAMETERS);
}
}
#endif
#if DISABLED(NO_WORKSPACE_OFFSETS)
@ -9387,7 +9413,7 @@ void process_next_command() {
break;
#endif
#if ENABLED(MESH_BED_LEVELING)
#if ENABLED(MESH_BED_LEVELING) || ENABLED(AUTO_BED_LEVELING_UBL) || ENABLED(AUTO_BED_LEVELING_BILINEAR)
case 421: // M421: Set a Mesh Bed Leveling Z coordinate
gcode_M421();
break;

@ -327,8 +327,13 @@
// Invalidate Mesh Points. This command is a little bit asymetrical because
// it directly specifies the repetition count and does not use the 'R' parameter.
if (code_seen('I')) {
int cnt = 0;
repetition_cnt = code_has_value() ? code_value_int() : 1;
while (repetition_cnt--) {
if (cnt>20) {
cnt = 0;
idle();
}
const mesh_index_pair location = find_closest_mesh_point_of_type(REAL, x_pos, y_pos, 0, NULL, false); // The '0' says we want to use the nozzle's position
if (location.x_index < 0) {
SERIAL_PROTOCOLLNPGM("Entire Mesh invalidated.\n");
@ -1433,4 +1438,4 @@
SERIAL_ECHOLNPGM("Done Editing Mesh");
}
#endif // AUTO_BED_LEVELING_UBL
#endif // AUTO_BED_LEVELING_UBL

Loading…
Cancel
Save